Saia-Burgess Controls AG
Manual for PCD2|3.W7x0
│ Document 26-
833 E
NG07 │ 2018-10-18
2
Programming
2-1
Function boxes
2 Programming
2.1
Function boxes
The deployment of one or more weighing modules is simplest with the FBoxes
WM_Master, WM_Config, WM_Weigh and WM_Status. The FBoxes WM_Config,
WM_Weigh and WM_Status are all available with both dynamic and static inputs.
In a FUPLA environment, the FBoxes with dynamic inputs are generally used. With
the FBoxes with static inputs, the user has the choice of setting the input to “1” or
“0”, or of manipulating the input externally. This has the advantage, for example,
that selected functions can be performed in one step within a Graftec program,
and others in a different step. If the weight is to be read in each cycle within a
FUPLA program, the Weigh input is set to “1” and the other inputs controlled by
the event are manipulated externally.
If the input „Weigh“ is set constant to „1“, it must be set be during the reset with
„Zero“ to „0“.
Example of the reset with “Zero” to “0”