4.2 Serial Control Wiring – PAV-SIPA1SM
Serial control connections for the PAV-SIPA1SM are made using the 6-pin connectors supplied with the device. Wires slip into the holes and are secured
using the screw located at the top of the connector.
4.3 IR Wiring
The PAV-SIPA1SM, PAV-SIPA50SM, PAV-SIPA125SM, and PAV-AIM7C all feature available ports for passing IR control to component devices. Follow the
diagram and notes below for the model of IP Audio device being installed to wire any IR control connections to component devices.
PAV-SIPA50SM
PAV-SIPA1SM / PAV-SIPA125SM /PAV-AIM7C
IR connections are made using 4-pin IR connectors supplied with
the device. The wire slips into the hole and locks with a screw
located at the top of the connector.
IR Pinout
NOTE
:
While not shown in the
diagram, IR connections 3
and 4 follow the same wiring
as 1 and 2.
IR connections are made using 6-pin IR Connectors supplied with the
device. The wire slips into the hole and locks with a screw located at the
top of the connector.
IR Pinout
NOTE
:
While not shown in the diagram, IR
connections 4 to 6 follow the same
wiring as 1 to 3.
NOTES
:
• CTS/RTS handshaking for flow control is not supported with the PAV-SIPA1SM.
• RS-422/485 is not supported with the PAV-SIPA1SM.
IMPORTANT! IR Wiring Precautions
• Ensure that all IR emitters are within 15 feet (4.6 meters) of the controller’s location.
• Use of 3rd party flashing IR emitters with Talk Back is not recommended. These types of emitters can draw voltage away from the IR signal, which
may degrade IR control performance.