28
V. 4.0
BAL 876.10 / .02
OPERATING INSTRUCTIONS
For Electronic Polarity Reversing Control Units
WORKHOLDING AND AUTOMATION
terminal-sketch
for use of 24 V
NC-signals
Check connection and set-
ting of chuck type before
use.
for specials, please
see enclosure!
terminal-sketch
for use of push-buttons and
coding-switches
SAV 876.02-SE2-1,
SAV 876.02-SE2-2,
SAV 876.02-SE2-3,
Check connection and set-
ting of chuck type before
use.
for specials, please
see enclosure!
magnetic chuck +
magnetic chuck -
5 lamp red, ground
6 free
7 machine release
8 machine release
9 free
10 lamp green, ground
11 free
12 NC-mass
13 push button clamping
14 push button unclamping
15 coding switch bit 3
16 coding switch bit 2
17 coding switch bit 1
18 coding switch bit 0
mains voltage 230 V / 400 V
(trafo for e-magnets if needed)
magnetic chuck +
magnetic chuck -
5 lamp red, ground
6 free
7 machine release
8 machine release
9 free
10 lamp green, ground
11 power supply 24 V
12 free
13 push button clamping
14 push button unclamping
15 coding switch bit 3
16 coding switch bit 2
17 coding switch bit 1
18 coding switch bit 0
mains voltage 230 V / 400 V
(trafo for e-magnets if needed)