22
V. 4.0
BAL 876.10 / .02
OPERATING INSTRUCTIONS
For Electronic Polarity Reversing Control Units
WORKHOLDING AND AUTOMATION
2. Installation
a) Mounting Sketch and Technical Data:
E L E C T R I C A L D E TA I L S
For Electro-Permanent Magnetic Chucks
Ordering no.
Magnet
Voltage
DCinV
Magnet
Current
max.
in A
Mains
voltage
AC in V
max.
magnet
rating
DC in kW
Fuse
in A
Section
of cable
in mm
2
Mains
transformer
required
876.10 -_-O-210/30/230
210
30
230
6.3
16
1,5
no (O)
876.10 -_-O-210/30/400
210
30
400
6.3
16
1,5
no (O)
876.10 -_-O-360/30/400
360
30
400
10.8
16
1,5
no (O)
876.10 -_-O-360/30x2/400
360
30x2
400
10,8 x2
16
1,5
no (O)
876.10 -_-O-360/30x3/400
360
30x3
400
10,8 x3
16
1,5
no (O)
876.10 -_-O-360/30x4/400
360
30x4
400
10,8 x4
16
1,5
no (O)
876.10 -_-O-360/60/400
360
60
400
21,6
32
3,5
no (O)
876.10 -_-O-360/60x2/400
360
60x2
400
21,6x2
32
4,0
no (O)
876.10 -_-O-360/60x3/400
360
60x3
400
21,6x3
32
4,0
no (O)
876.10 -_-O-360/60x4/400
360
60x4
400
21,6x4
32
4,0
no (O)
For Electro Magnetic Chucks
Ordering no.
Magnet
Voltage
DCinV
Magnet
Current
max.
in A
Mains
voltage
AC in V
max.
magnet
rating
DC in kW
Fuse
in A
Section
of cable
in mm
2
Mains
transformer
required
876.10 -_- T-24 / 7 /230
24
7
230
168
4
1,5
yes (T)
876.10 -_- T-24 /15/ 230
24
15
230
360
6,3
2,5
yes (T)
876.10 -_- T-24 /25 /230
24
25
230
600
6,3
4,0
yes (T)
876.10 -_- O-110/ 6 /230
110
6
230
660
4
1,5
no (O)
876.10 -_- O-110/16/230
110
16
230
1760
16
2,5
no (O)
876.10 -_ -O-110/30/230
110
30
230
3300
25
4,0
no (O)
876.10 -_- T-110/ 6 /400
110
6
400
660
4
1,5
yes (T)
876.10 -_- T-110/16/400
110
16
400
1760
16
2,0
yes (T)
876.10 -_- T-110/30/400
110
30
400
3300
25
4,0
yes (T)
Electronic Polarity-Reversing Control Unit SAV 876.10 - E - O - 360 / 60 x 4 / 400
Name SAV No. - Version - Transformer - Magn. nom. voltage / Max. current / Mains voltage
Ordering example:
Ordering key: