Instruction Manual 

HMP 

 

HMP-BA-e-1211 

 

10

 

 
 
 
 
 
 
 
 

Table 4 

Nr. 

Type 

Sketch 

of 

non-conventional 

supporting ring 

Remarks 

Z10-15 

 

For testing cylindrical outside 
 R10

R15 

Z14.5-30 

For testing cylindrical outside  
R14.5

R30 

Z25-50 

For testing cylindrical outside  
R25

R50 

HZ11-13 

 

 For testing cylindrical inside  
R11

R13 

HZ12.5-17 

For testing cylindrical inside  
R12.5

R17 

HZ16.5-30 

For testing cylindrical inside  
R16.5

R30 


 

K10-15 

 

For 

testing 

spherical 

outside 

surface 

SR10

SR15 

K14.5-30 

For 

testing 

spherical 

outside 

surface 

SR14.5

SR30 

HK11-13 

 

For 

testing 

spherical 

inside 

surface 

SR11

SR13 

10 

HK12.5-17 

For 

testing 

spherical 

inside 

surface 

SR12.5

SR17 

11 

HK16.5-30 

For 

testing 

spherical 

inside 

surface 

SR16.5

SR30 

 
12 
 

UN 

 

For testing cylindrical outside surface,  
radius adjustable R10

∞ 

 
 
 
 
 
 
 
 

Summary of Contents for HMP

Page 1: ...Program 6 3 Fault Analysis Clearance 6 4 Note of Transport and Storage Conditions APPENDIX Table 1 Table 2 Table 3 Table 4 1 Overview 1 1 Advantages Wide measuring range Based on the principle of LEE...

Page 2: ...y Remarks Stand ard Config ura tion 1 Main unit 1 2 D type impact device 1 With cable 3 Standard test block 1 4 Cleaning brush I 1 5 Small support ring 1 6 Alkaline battery 2 AA size 7 Manual 1 8 Inst...

Page 3: ...To change the impact times in one group the key has to be pressed The impact times item will start flashing when the key is pressed Then the impact times value can be adjusted as desired by the keys a...

Page 4: ...the hardened layer should also conform to Table 3 Coupling Light weight samples must be firmly coupled with a heavy base plate Both coupled surfaces have to be flat and smooth there may not rest any...

Page 5: ...he type of impact device will be automatically detected while powering on This information will be displayed on the screen Users should take notice to this type After a few seconds the screen will exi...

Page 6: ...me during data logging 5 6 2 Clearing selected File Group It may be required to delete a file from the instrument s memory This procedure is outlined in following steps 1 The key has to be pressed to...

Page 7: ...Measurement data stored in memory of the gauge can be transferred to PC with the RS 232 port Detailed information of the communication software and its usage please refer to the software manual 5 13...

Page 8: ...tool steel HRC 20 4 67 1 19 8 68 2 20 7 68 2 22 6 70 2 HV 80 898 80 935 100 941 82 1009 Stainless steel HRB 46 5 101 7 HB 85 655 HV 85 802 Grey cast iron HRC HB 93 334 92 326 HV Nodular cast iron HRC...

Page 9: ...e surface Ra 1 6 m 1 6 m 0 4 m 6 3 m 1 6 m Min weight of sample Measure directly Need support firmly Need coupling tightly 5kg 2 5kg 0 05 2kg 5kg 2 5kg 0 05 2kg 1 5kg 0 5 1 5kg 0 02 0 5kg 15kg 5 15kg...

Page 10: ...sting cylindrical outside R25 R50 4 HZ11 13 For testing cylindrical inside R11 R13 5 HZ12 5 17 For testing cylindrical inside R12 5 R17 6 HZ16 5 30 For testing cylindrical inside R16 5 R30 7 K10 15 Fo...