1. Release button

 

2. Loading tube 
3. Guide tube  
4. Connection cable 
5. Coil unit 
6. Impact body 
7. Support ring 
 

2.1.2 Different Types of Impact Devices 

DC       DL        C       D+15      E           G 

 

2.2  Main Screen 

The main display screen is shown: 
 
Hardness Scale   Average Icon  Memory Icon 

                                                          

Battery info 

 
             

 

 

 
 
                                                         Measured value 
Direction   Material No.    Impact times  
 
Instruction for the main display screen: 

Material: 

The present presetted material 

Impact direction: 

The present impact direction 

Hardness scale: 

Hardness scale of the present measured 

value 

Battery information: 

Showing the rest capacity of battery 

Measured value: 

Display shows the single time measured 

value  (without  showing  the  average  icon)  or  the  display 
shows the mean value (with average icon prompting). 
“HI” means: over conversion value or measurement range 
“LO” means: lower than conversion value or measurement 
range. 

Impact times: 

Times that have been impacted 

Average  icon: 

It  appears  when  the  mean  value  of  the 

measured  values  is  shown  after  the  preset  impact  times 
are achieved. 

Memory  icon: 

It  appears  when  operating  with  the 

instrument’s memory. 
 

2.3     Keypad Description 

* The 

 

key has to be pressed to store the present group 

of  measured  value  into  the  instrument’s  memory.  This 

operation  is  only  valid  after  the  mean  value  has  been 
displayed. 

*  To  display  the  single  measured  value,  the  keys 

  and 

 have to be pressed. 

* To switch on and off the backlight of the LCD, the key 

 

has to be pressed. 

*  To  set  the  impact  direction,  the  key 

  has  to  be 

pressed. 

*  To  change  the  impact  times  in  one  group,  the  key 

 

has to be pressed. The impact times item will start flashing 

when the key 

 is pressed. Then the impact times value 

can be adjusted as desired by the keys 

 and 

.  

Finally,  the 

  key  has  to  be  pressed  to  exit  from 

changing the impact times procedure. 
* The hardness scale can be changed by pressing the  

 key. 

*Material  can  be  changed  by  pressing  the 

  key.  After 

material  setting  has  been  changed,  presetting  hardness 
scale recovers HL automatically. 

*  The 

  key  has  to  be  pressed  to  switch  between 

hardness test and strength test. 
Remark:  Only  D  and  DC  type  of  impact  device  have  got 
the function of strength testing. So, if the impact device is 
not D or DC type, only hardness testing is possible. 

*The 

  key  has  to  be  pressed  to  print  out  the measured 

values after the measurement has been performed. 
 

2.4     Leeb Hardness Testing Principle 

The basic principle shortly described:  
An  impact  body  with  a  certain  weight  impacts  against  the 
testing  surface  under  certain  test  force.  Then  the  impact 
velocity  and  the  rebound  velocity  of  the  impact  body  are 
measured  respectively  while  the  spherically  test  tip  is 
located 1 mm above the testing surface. 
The calculation formula is as follows:  
 

              HL= 1000 x VB/VA 
 

Where   HL= Leeb Hardness Value 
              VB= Rebounding velocity of the impact body 
              VA= Impact velocity of the impact body 
 

3.       Preparation 
3.1     HMP Preparation and Inspection 
 

The  instrument  is  calibrated  by  using  the  test  block, 
included  in  delivery.  The  error  and  repeatability  of  the 
displayed  value  should  be  within  the  regulation  of 
APPENDIX Table 2. 
The  instrument  and  the  impact  device  have  to  be 
calibrated using a standard hardness block before the first 
use. If the hardness tester has not been used for a longer 
period, it is also recommended to calibrate it and as well, if 
the instrument’s system has been reset. 

 

Summary of Contents for HMP

Page 1: ...Program 6 3 Fault Analysis Clearance 6 4 Note of Transport and Storage Conditions APPENDIX Table 1 Table 2 Table 3 Table 4 1 Overview 1 1 Advantages Wide measuring range Based on the principle of LEE...

Page 2: ...y Remarks Stand ard Config ura tion 1 Main unit 1 2 D type impact device 1 With cable 3 Standard test block 1 4 Cleaning brush I 1 5 Small support ring 1 6 Alkaline battery 2 AA size 7 Manual 1 8 Inst...

Page 3: ...To change the impact times in one group the key has to be pressed The impact times item will start flashing when the key is pressed Then the impact times value can be adjusted as desired by the keys a...

Page 4: ...the hardened layer should also conform to Table 3 Coupling Light weight samples must be firmly coupled with a heavy base plate Both coupled surfaces have to be flat and smooth there may not rest any...

Page 5: ...he type of impact device will be automatically detected while powering on This information will be displayed on the screen Users should take notice to this type After a few seconds the screen will exi...

Page 6: ...me during data logging 5 6 2 Clearing selected File Group It may be required to delete a file from the instrument s memory This procedure is outlined in following steps 1 The key has to be pressed to...

Page 7: ...Measurement data stored in memory of the gauge can be transferred to PC with the RS 232 port Detailed information of the communication software and its usage please refer to the software manual 5 13...

Page 8: ...tool steel HRC 20 4 67 1 19 8 68 2 20 7 68 2 22 6 70 2 HV 80 898 80 935 100 941 82 1009 Stainless steel HRB 46 5 101 7 HB 85 655 HV 85 802 Grey cast iron HRC HB 93 334 92 326 HV Nodular cast iron HRC...

Page 9: ...e surface Ra 1 6 m 1 6 m 0 4 m 6 3 m 1 6 m Min weight of sample Measure directly Need support firmly Need coupling tightly 5kg 2 5kg 0 05 2kg 5kg 2 5kg 0 05 2kg 1 5kg 0 5 1 5kg 0 02 0 5kg 15kg 5 15kg...

Page 10: ...sting cylindrical outside R25 R50 4 HZ11 13 For testing cylindrical inside R11 R13 5 HZ12 5 17 For testing cylindrical inside R12 5 R17 6 HZ16 5 30 For testing cylindrical inside R16 5 R30 7 K10 15 Fo...

Reviews: