Linear Bearing
NOTE:
This procedure does not apply to the following peripherals: EMC 1,
EMC 6M, EMC 6ML, EMC 6MLT, EMC 6/4M, EMC 6/4MT, CH 1.
EMC 6, EMC 10, EMC 10T, EMC 10/4, EMC 10/4T:
Although the linear bearing assemblies used in the sewing heads require very little
maintenance, it is advisable to lubricate them approximately once every six months.
Refer to the following procedure for proper lubrication.
1. Using the keypad, press the [ALT][
⇐
] keys to move the needle case to the
full left position.
2. Remove the cover panels (EMC 10/4 and EMC 10/4T only) to allow access
to the V-rail (refer to Figure 2-19).
3. Place one drop of oil on the linear bearing track. Repeat for all sewing
heads (EMC 10/4 and EMC 10/4T only).
4. Using the keypad, press the [ALT][
⇒
] keys to move the needle case to the
full right position.
5. Place one drop of oil on the linear bearing track. Repeat for all sewing
heads (EMC 10/4 only).
6. Replace all cover panels (EMC 10/4 and EMC 10/4T only).
Place one drop
of oil here
Figure 2-19
2 - 20
Lubricating The Sewing Head
Basic Maintenance
Melco Embroidery Systems