The radio modem is shipped with the following default settings (unless otherwise specifically
ordered):
DEFAULT VALUES OF THE ADJUSTABLE SETTINGS ( the user can change these settings later on )
Setting
Default value
Notes
Operating frequency
436.500 MHz
Range: 403-407 MHz
Channel Spacing
25 kHz
Range:12.5, 20, or 25 kHz
Tx Power
1000 mW
Range: 100, 200, 500 or 1000 mW
Protocol SATEL
3AS
SATEL 3AS, Option 1, Option 2
Addressing RX
Address
OFF
/
TX Address OFF
Tx-Delay 0
ms
Signal threshold
-117 dBm
SyncInterval
default (=21845 bytes)
Rx-Delay
0 ms
Pause length
3 characters
FEC
OFF
Error check
OFF
Error correction
OFF
Serial port 1 settings Port
function=DATA
Data speed=9600 bps
Data bits=8
Parity=None
Stop bits=1
Pause length=3 bytes
Handshaking settings
CTS=Clear to send
CD=RSSI threshold
RTS=Ignored
Handshaking lines apply to the DATA-port.
SL-commands ON
When creating a test connection, you can also use the Windows-based SATEL Configuration
Manager, (available for free from authorised SATEL dealers or directly from SATEL Customer
Support).
Basic settings for the serial port of the host computer, when using a terminal program to
communicate with SATEL radio modems, are as follows: “COM1, 9600 bps, 8-bit data, none
parity, 1 stop bit”.