background image

 

 

 

 

 

 
 
 
 

 Firmwa

re Versio

n 1.01 

 

       

Alarm Control Panel 

 
 
 
 
 
 
 
 
 
 
 
 

PROGRAMMING 

 
 

       

 
 
 
 
 
 
 
 
 
 
 

SATEL sp. z o.o. 

ul. Budowlanych 66 

80-298 Gda

ń

sk  

POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

perfecta_p_en 10/17 

Summary of Contents for PERFECTA 16-WRL

Page 1: ...Firmware Version 1 01 Alarm Control Panel PROGRAMMING SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu perfecta_p_en 10 17 ...

Page 2: ... technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us http www satel eu Hereby SATEL sp z o o declares that this control panel is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU The declaration of conformity may be consulted at www satel eu ce Service code 12345 ...

Page 3: ...fter entering a correct code when the keypad is blocked Arming When viewing the list of problems that prevent arming the user can bypass unbypass zones provided he she has appropriate rights Listening in You can better customize the listening in to meet the needs of the users by using the following new options Listen in defines whether the given telephone can be used to call the alarm control pane...

Page 4: ...TA SOFT program 7 3 1 1 Menu bar in the PERFECTA SOFT program 8 3 1 2 Side menu 9 3 1 3 Additional menu 10 3 2 Establishing connection between the program and the control panel 13 3 2 1 Local connection 13 3 2 2 Remote connection SATEL server 13 3 2 3 Remote connection PERFECTA PERFECTA Soft 13 4 Hardware 14 4 1 Mainboard 14 4 1 1 Clock 14 4 1 2 Times 15 4 1 3 Arming 16 4 1 4 Options 16 4 2 GSM ph...

Page 5: ...SMS messaging 38 11 SMS control 39 11 1 Parameters and options of SMS control 39 12 Timers 40 12 1 Parameters and options of the timers 40 12 1 1 Editing the timer parameters 41 13 Control panel firmware update 41 13 1 Local update 41 13 2 Remote update 42 13 2 1 Remote update parameters and options 42 13 2 2 Procedure of remote update for control panel firmware 43 14 Users 43 14 1 User schedules ...

Page 6: ...ce mode menu will be displayed the cursor will show the END SM function 2 2 Starting the service mode from pins When entering the service mode in the normal way is not possible the control panel does not support keypads does not accept the service code etc you can use the emergency procedure so called starting from pins 1 Turn off the control panel power supply first disconnect the AC power and th...

Page 7: ...n the LIST OF SERVICE FUNCTIONS document 1 Use the number keys to enter the number use the key to erase the last digit 2 The menu item designated by this number will be displayed use the key to go back to the main menu 3 Press or to open a submenu or run a function If the cursor indicates END SM and you want to quickly run a function enter its number and press or For example to run the expander id...

Page 8: ...e number keys Use the and keys to move the cursor In some functions the key deletes the character on the left side of the cursor 2 5 4 Entering hexadecimal values To enter digits use the number keys To enter the A B and C characters use the key and to enter D E and F use the key keep pressing the key until the required character appears Use the and keys to move the cursor The key deletes the chara...

Page 9: ...orized personnel from getting access to the service menu in the meantime To get access to the menu again proceed in the same way as when entering the service mode 2 7 Exiting the service mode Keep pressing until the cursor indicates the SM END function and then press 3 Configuring the system with the PERFECTA SOFT program You can download the PERFECTA Soft program from the www satel eu website Com...

Page 10: ...oject file click on the search field and start entering characters The current view will be filtered out based on the text entered Buttons click if the files are to be sorted by name the arrow next to the button indicates whether the files from A to Z or from Z to A are displayed click if the files are to be sorted by the time they were saved to disk the arrow next to the button indicates whether ...

Page 11: ...tion to the control panel The button is displayed when the program is not connected to the control panel click to finish connection to the control panel The button is displayed when the program is connected to the control panel click to read data from the control panel click to write data to the control panel click to display information on the status of partitions zones outputs etc The button is ...

Page 12: ...ck to convert the control panel data for the needs of another PERFECTA control panel Connection click to open the Connection window Configuration click to open the Configuration window About click to display information about the PERFECTA SOFT program Licence agreement click to show the license agreement Connection window In the window you can choose how connection with the control panel is to be ...

Page 13: ...ly by the SATEL server To check the IMEI number and ID number on the keypad use the 7 IMEI ID function enter the user menu and press in turn If the control panel was programmed locally before the IMEI number and ID number will be read from the control panel data Panel key identifier of the control panel It must be identical to that programmed in the control panel see p 32 Remote connection PERFECT...

Page 14: ...ved to disk to be additionally encrypted enter the file encryption key Opening the files in another PERFECTA Soft program without entering the valid key will be impossible Data folder you can choose whether the control panel data files are to be saved to the default folder or a folder selected by you Program language you can select a program language The program will restart after the language is ...

Page 15: ...e saved on the computer disk Projects tab 2 Configure the settings required to establish connection via GPRS through the SATEL server see Connection window p 10 3 Click on the menu bar 4 A window will open with information that connection has been established and a prompt to read the data 5 Click Yes 3 2 3 Remote connection PERFECTA PERFECTA Soft The computer running the PERFECTA SOFT program must...

Page 16: ...r whose address has been given in the SMS message and use for communication the TCP port given in the SMS message 2 After the control panel connects to the computer a window will open with information that connection has been established and a prompt to read the data 3 Click Yes 4 Hardware The control panel has a built in GSM GPRS communicator To the control panel communication bus you can connect...

Page 17: ... GSM NETWORK options are enabled at the same time synchronization with the GSM network time has priority The clock will only be synchronized with the time server if synchronization with the GSM network time fails Time zone 064 Timezone difference between the universal time UTC and the zone time The parameter is required if the control panel clock is to be synchronized Fig 8 Mainboard tab 4 1 2 Tim...

Page 18: ...he control panel will not check conditions after finishing the exit delay countdown it will only check the conditions before starting the arming procedure The option is available when the PREVENT ARMING IF NOT READY option is enabled Do not arm if battery trouble BAT low no arm if this option is enabled forced arming will be impossible in the event of battery trouble The option is available when t...

Page 19: ...ncorrect code three times cf BLOCK AFTER THREE INCORRECT CODES option during arming the control panel checks for problems that prevent arming cf PREVENT ARMING IF NOT READY option ARM EVEN IF NOT READY AFTER EXIT DELAY DO NOT ARM IF BATTERY TROUBLE and DO NOT ARM IF TAMPERED options are interpreted as disabled control panel gives information about past troubles cf TROUBLE MEMORY option loss of com...

Page 20: ...on is enabled jamming of the wireless system will not be reported 4 2 GSM phone SIM 1 SIM1 SIM 2 SIM2 if this option is enabled the given SIM card is supported by the control panel Disable the option if the given card is not to be used Disabling the option will prevent unnecessary reporting of troubles related to that card PIN 612 PIN 622 PIN PIN code of the SIM card If a wrong PIN code is program...

Page 21: ...en card For reporting the transmission paths programmed as subsequent ones if they require switch over to the other card will be skipped during the lock time countdown Entering the value 0 means that instant switch over to the other SIM card is possible Return time 64 Restore SIM1 66 Restore SIM2 the time after which the other SIM card is to be used Entering the value 0 means that automatic switch...

Page 22: ...day 4 3 Keypad Name 28 Names individual name of the keypad up to 16 characters Alarm in part 22 Partitions the partition in which alarm will be triggered in the event of keypad tamper opening of enclosure or loss of communication 4 3 1 Options Show partition 1 status Show part 1 if this option is enabled the keypad LEDs and display indicate the status of partition 1 The keypad will indicate the st...

Page 23: ...ressing the key for approx 3 seconds will trigger the fire alarm PANIC alarm Panic alarm if this option is enabled pressing the key for approx 3 seconds will trigger the panic alarm Silent PANIC Silent panic if this option is enabled the panic alarm triggered from the keypad will be a silent one without loud signal The option is available if the PANIC ALARM option is enabled Fig 10 Tab with settin...

Page 24: ... Exit delay volume level of the exit delay beeps 255 Fire alarm volume level of the fire alarm beeps 256 Burg alarm volume level when signaling burglary panic and medical auxiliary alarms 257 Warn alarm volume level when signaling warning alarms 258 New trouble volume level when signaling troubles 4 3 5 Wireless keypad PERFECTA 16 WRL PERFECTA 32 WRL For the wireless keypad additional parameters a...

Page 25: ...e voltage decays having no effect on normal operation of the system The parameter is valid for the module with power supply 4 5 Output module Name 2815 Ex 0F name individual name of the module up to 16 characters Alarm in part 2215 Ex0F part partition in which alarm will be triggered in the event of module tamper AC loss report delay 2315 AC 0F loss time during which the module must be without AC ...

Page 26: ...f the protected area as well as limiting access to some portion of the premises to selected users You can create 2 partitions 5 1 Partition parameters Part name 18 Names individual name of the partition up to 16 characters Exit delay 13 Exit delay time counted from the moment of starting the procedure of partition arming It allows the user to leave the protected area without triggering alarm You c...

Page 27: ... ENTRY EXIT FINAL 2 INTERNAL 3 INSTANT 4 DOUBLE KNOCK or 5 24H BURGLARY zones are verified The time is counted from the moment of alarm triggering by this type of zone Exit delay clearing enable Fin exit delay if this option is enabled the users can terminate the exit delay countdown by using keypad the or key is to be pressed and hold down for about 3 seconds Infinite exit delay Infinit ex delay ...

Page 28: ...pective of the programmed number of pulses and sensitivity see below will be interpreted as violation This solution enables a magnetic contact to be connected in series with the vibration detector Sensitivity 32 Sensitivity depending on wiring type NO NC EOL and 2EOL the time during which the zone must be violated so that it can be noted by the control panel The sensitivity is programmed in millis...

Page 29: ...enter from 0 to 255 seconds Programming 0 will make the zone act as an instant one Delay 34 Entry delay the time by which alarm from the zone of 2 INTERNAL type will be delayed It is counted from the moment of zone violation You can enter from 0 to 255 seconds Programming 0 means that the zone will act as an instant one Waiting time 34 Entry delay the time during which the 4 DOUBLE KNOCK type zone...

Page 30: ...e is normally used for outdoor motion detectors and window protection detectors 4 DOUBLE KNOCK when the partition is armed violating a zone will result in logging the event and starting the WAITING TIME countdown If the zone is violated again when the countdown is running alarm will be triggered 5 24H BURGLARY zone violation will trigger burglary alarm Use this zone type for the detectors which sh...

Page 31: ...about violation is sent depends on the detector operating mode normal the detector sends information on violation and violation restore in real time the zone status corresponds to the detector status energy save available in some detectors after sending information on violation the detector will not send any further information about violations for 3 minutes the zone will be violated for 2 seconds...

Page 32: ...when the system is armed continuous mode or when there is alarm pulsating mode 21 DETECTORS RESET output is used to reset the alarm memory in detectors It is activated on starting the exit delay countdown if the exit delay is 0 on arming starting the 3 OUTPUTS RESET user function 22 SERVICE MODE STATUS output is active when the control panel is running in service mode 23 ARM STATUS REPORTED output...

Page 33: ...d 454 Pulsed if this option is enabled the output is pulsating when it is active The option does not apply to the 1 EXTERNAL SIREN 2 INTERNAL SIREN 11 FIRE DETECTORS POWER SUPPLY and 20 ARM ALARM STATUS OUTPUTS The option does not apply to wireless outputs Arm Disarm clear sign 455 Arm Dis Clr if this option is enabled the output will signal starting the arming procedure if the exit delay time is ...

Page 34: ... Arm Disarm beep 1276 Acknowled signaling mode for arming disarming etc cf ARM DISARM CLEAR SIGN option Tamp in part 1274 Out tamper partition in which alarm will be triggered in the event of siren tamper 8 Communication Panel key 01 PERFECTA key identifier of the alarm control panel You can enter up to 16 alphanumeric characters digits letters and special characters You can enter spaces but at le...

Page 35: ...er values from 0 to 65535 0 disabled SMS initiating connection 115 PERF Soft control command which will be sent in SMS message to initiate communication between the control panel and the PERFECTA SOFT program You can enter up to 8 alphanumeric characters digits letters and special characters You can enter spaces but at least one character must be different from the space The command content must b...

Page 36: ... to the monitoring station SIA selected codes event codes are sent in SIA format Only selected events are sent to the monitoring station Panel identifier 731 Identifiers 751 Identifiers 732 SIA prefix 752 SIA prefix identifier of the control panel for reporting purposes It allows the monitoring station to determine from the events are sent For the Contact ID format it consists of 4 hexadecimal cha...

Page 37: ...reporting the control panel gets no acknowledgement of receiving the event codes by the monitoring station hence this transmission path should be used as the last one The switch over from one SIM card to the other one requires time for example to log onto the network so it is better to use up all the transmission paths available for one SIM card The switch over from one SIM card to the other is af...

Page 38: ...ervals to check communication with the monitoring station You can program a number of days hours minutes and seconds between the transmissions Entering zeros only means that no additional transmission will be sent 9 1 2 Test transmissions The test transmission is sent using all transmission paths included in the list that defines the order of using transmission paths cf REPORTING PRIORITY paramete...

Page 39: ... call the number of SIM card used to listen to what is going on in the premises Listen in 87 List aft msg if this option is enabled the telephone user after the notification message is played can listen in to what is going on in the premises SMS forw 84 Unknown SMS if this option is enabled unknown SMS messages received by the control panel are forwarded to the phone number e g information receive...

Page 40: ...t entered can be converted into a voice message by using the text to speech converter voice synthesizer Duration duration of the voice message Total information on total duration of the voice messages click to play back the selected voice message click to import the WAV type file which is to be used as the selected voice message click to delete the selected voice message click to convert the messa...

Page 41: ...his option is enabled the phone will be notified of arming disarming and alarm clearing Zone bypasses if this option is enabled the phone will be notified of bypassing unbypassing zones Troubles if this option is enabled the phone will be notified of troubles Used functions if this option is enabled the phone will be notified of the functions used System events if this option is enabled the phone ...

Page 42: ...mand to run the given function can be sent from any phone If the option is disabled only from the phone whose number is saved on the control panel see Phones p 37 12 Timers The timer compares the time to that of the control panel clock and executes the selected function at the programmed time Using the timers it is possible to control the armed mode of partitions and the 15 CONTROLLED outputs You ...

Page 43: ...must program both dates for an exception FROM and TO One or two of the date components may remain undefined e g if you enter a value from beyond the range more than 2099 for the year 12 for the month or 31 for the day For example xxxx 12 25 the exception will be valid from to 25 Dec each year xxxx xx 12 the exception will be valid from to 12th day of each month in each year xxxx 03 xx the exceptio...

Page 44: ... enabled you can enter server address and port number in the SMS message initiating the firmware download from the update server If the message contains no address or port number the control panel will use the preprogrammed settings Firmware download SMS initiating connection 116 Download FW the control command which can be sent in the SMS message to initiate firmware download from the UPSERV upda...

Page 45: ...SS IN SMS option is enabled in the control panel and you want the control panel to connect to an update server other than that indicated in the control panel settings the message should look like this xxxx aaaa pp xxxx control command aaaa server address IP address or domain name pp port number If an SMS message containing the firmware download initiating command is re sent when the new firmware d...

Page 46: ...21 Schedules individual name of the user schedule up to 16 characters Right 121 Schedules defines which functions are available to the user The following rights are available Arming the user can arm the system Disarming the user can disarm the system Alarm clearing the user can clear alarms ...

Page 47: ...nd PERFECTA SOFT functions Changing panel ID the user can run the ID CHANGE function the TESTS right is additionally required 14 2 Default functions of keyfob buttons You can define which functions can be started by using the new keyfob When adding editing a user you can change the keyfob settings to make the functions suitable for the needs and rights of the user Changing the default functions ha...

Page 48: ...FECTA Soft program has been added p 12 Description of Prevent arming if not ready option has been supplemented p 16 Description of Wake up duration parameter has been added p 22 Information on number of retries for AUDIO messaging has been added p 37 Description of Listen in option has been added p 37 Description of Listen in option has been added p 37 Description of Answer if partition armed para...