FUNCTION 0 – exit service mode
Activating sequence: 0.#...
FUNCTION 1 – service code programming
Activating sequence: 1.#...
Example:
programming new code: 89354
8.9.3.5.4.#...
FUNCTION 2 – permanent zone bypassing
Activating sequence: 2.#...
Example 1:
bypassing zone number 2 and 3
2.3.#...
Example 2:
unbypassing zone 3
3.#...
FUNCTION 3 – 24 hour zones (are active although the system is not armed)
Activating sequence: 3.#...
Example:
zone 4 is to be changed into 24 hours type
4.#...
FUNCTION 4 – delayed zones (the zones of this type activate the alarm after the time
specified by using function 6)
Activating sequence: 4.#...
Example:
zone 1 and 2 are to be changed into delayed type
1.2.#...
FUNCTION 5 – programming the exit delay time (from 0 to 99 seconds)
Activating sequence: 5.#...
Example:
the exit delay time is to be set to 30 seconds
3.0...
FUNCTION 6 – programming the entry delay time (from 0 to 99 seconds)
Activating sequence: 6.#...
Example:
the entry delay time is to be set to 8 seconds
0.8...
FUNCTION 7 – programming the alarm time at OUT1 output (from 001 to 999
seconds, for 000 the exit is active even until the alarm has been
cancelled)
Activating sequence: 7.#...
Example:
the alarm time is to be set to 5 minutes (300 seconds)
3.0.0...
FUNCTION 8 – programming the alarm time at OUT2 output (the output signals the
alarm after being programmed to 001 through 998 seconds) or the way of
armed status signaling (000 – 0V at OUT2 when the panel is armed; 999 –
+12V at OUT2 when the panel is armed).
Activating sequence: 8.#...
Example:
the alarm time is to be set to 5 seconds
0.0.5...
FUNCTION 9 – default settings restore. The following values are pre-programmed:
access code 1
1234
access code 2
not pre-programmed