12 SATEL 

CA-4v1 

 

TABLE OF PROGRAMMING 

 functions available after entering service code 

End of service mode 

Service code  

1 2 3 4 5   

 

 

Z1 Z2 Z3 Z4 

Permanent bypassed zones 

 

 

 

 

24-hour zones  

 

 

 

2

 

Delayed zones (enter/exit) 

2

 

 

 

 

 

Exit delay time 

05  00

99 seconds 

Entry delay time 

10  00

99 seconds 

Alarm time at OUT1 

005 

001

999 seconds 

000 – alarm to cancelling 

Alarm time at OUT2 

010 

001

998 seconds 

000 – 0V at OUT2 when is armed 
999 

 +12V at OUT2 when is armed 

Default settings restore 

 functions available after entering user master code 

User code (master) 

1 2 3 4     

User code (master) 

 

 

 

 

 

 

User code  

  

 

 

 

 

 

User code (one time use) 

 

 

 

 

 

 

 

 

Z1 Z2 Z3 Z4 

The zones bypassed by user 

 

 

 

 

Z1 

Z2 

Z3 

Z4 

Reviewing of the 7 last alarms memory log (the LED 
indicates the origin of the alarm):  

[digit] – previous alarm; [*] – exit the function 

  [ARMED] – 3 

wrong access codes 

 [TROUBLE] 

– 

PANIC type alarm 

F1 

AUX 

F2 

OUT1 

F3 

OUT2 

F4 

battery 

Identifying trouble type – LEDs indicate the type of 
trouble (available only when 

 [TROUBLE] LED 

blinking) 

 [ALARM] – no AC power supply 

Alarm upon entering 3 wrong access codes 

Z1   

PANIC alarm available – press [#] key 

Z2   

The entry delay countdown signaling – sounds 

Z3   

8 Additional 

functions 

Access code 3 – alarm only in keypad (silent armed mode) 

Z4   

 

Z1 Z2 Z3 Z4 

The zones bypassed automatically after entering access 
code 3
 

 

 

 

 

Default settings are wrote or marked 

2

 in right bottom corner of field assigned to be filled. 

The user functions can be called only with the master code (functions 6 and 7 without parameters): 

[master user access code][*][number of function][parameter][#] 

After entering a service mode [service code][#] (or [service code][*])  the functions (without 
function 9) are calling by: 

[number of function][#][parameter][#] or [number of function][#] [parameter] 

[0][#] – end of programming in service mode. 

Summary of Contents for CA-4v1

Page 1: ...Alarm Control Panel CA 4v1 ca4v1_en 08 08 MANUAL GDA SK POLAND...

Page 2: ...cting the supply voltage For the replacement use only the fuses which have identical parameters as the original ones It is recommended that the manufacturer s required housings and power supply units...

Page 3: ...tem with bypassing the programmed zones stay arming one time code for single arming and disarming the system additional servicing code for accessing basic programming functions of the panel extended c...

Page 4: ...of the site and select a circuit which is permanently alive to power the control panel The circuit is to be protected with an appropriate fuse CAUTION The control panel is power supplied from the 230V...

Page 5: ...by indicating the fuse which protects the control panel supply circuit The panel on board DC power supply default setting is 13 6 13 8V and should not be changed Connection of keypad The CA 4v1 contro...

Page 6: ...pering circuit which should be used to protect them The OUT1 and OUT2 outputs control the ground terminal The 12V voltage is led through F2 and F3 fuses to OUT1 and OUT2 terminals The OUT1 and OUT2 te...

Page 7: ...maining situations the sound signal is repeated every second 1 short the entry delay time countdown 2 short the panel detected a trouble TROUBLE LED is on sound signal can be temporary switched off by...

Page 8: ...anceling the alarm the armed mode is deactivated PANIC alarm Press and hold the key for about 3 seconds The function can be blocked see ADDITIONAL FUNCTIONS Access code programming functions 1 2 3 4 T...

Page 9: ...incorrect access codes the TROUBLE LED will indicate PANIC type alarm Pressing any of the keys except will classify the previous alarm The panel logs the last three instances of alarm condition Pressi...

Page 10: ...e additionally bypassed should be entered After programming the panel the key should be pressed Programming Programming the panel enables its users to adjust it to specific requirements of an alarm sy...

Page 11: ...vating sequence 5 Example the exit delay time is to be set to 30 seconds 3 0 FUNCTION 6 programming the entry delay time from 0 to 99 seconds Activating sequence 6 Example the entry delay time is to b...

Page 12: ...COM terminal when the panel is armed Value 999 means that OUT2 will set the voltage to 12V when the panel is armed The bias resistor for example 1k that limits the input current from terminal OUT2 mus...

Page 13: ...r supply outputs 400mA delayed fuse protection outputs OUT1 and OUT2 1A delayed fuse protection battery protection 3 15A delayed fuse protection number of zones 4 zone type end of line resistor EOL re...

Page 14: ...us alarm exit the function ARMED 3 wrong access codes TROUBLE PANIC type alarm F1 AUX F2 OUT1 F3 OUT2 F4 battery 7 Identifying trouble type LEDs indicate the type of trouble available only when TROUBL...

Page 15: ...SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Reviews: