5.6 Instrument Status Registers
Table 5-6 Instrument Status Registers
Parameter
Register
Size,
Direc-
Unit
Range
byte
tion
Instrument reset
register
2560 2 R/W
0
(when
read)
65535 (when written) =
reset the instrument
Reserved
2561
2
R
Read as 0
Relay status
2562
2
R
see Table 5-7
Reserved
2563
2
R
Read as 0
Status inputs
2564
2
R
see Table 5-11
Firmware version
number
2565 2 R 0-65535
Instrument options 1
2566
2
R
see Table 5-8
Instrument options 2
2567
2
R
see Table 5-8
Writing a value of 65535 into register 2560 will cause the instrument to perform a warm restart.
Table 5-7 Relay Status
Bit number
Description
0-5
Not used (permanently set to 1)
6 Relay
#2
status
7 Relay
#1
status
8-15
Not used (permanently set to 0)
Bit meaning: 0 = relay is energized, 1 = relay is not energized
Table 5-8 Instrument Options
Options register
Bit
Description
Options1 0
120V
option
1
690V
option
2-3
Reserved
4
100% current over-range
5
Reserved
6
Analog output 0/4-20 mA
7
Analog output 0-1 mA
8
Analog output
±
1 mA
9
Relays
option
10
Digital inputs option
11-13
Reserved
14
Analog expander output
±
1 mA
15
Reserved
Options 2
0-2
Number of relays - 1
3-6
Number of digital inputs - 1
7-8
Number of analog outputs - 1
9-13
Reserved
14-15
Memory module size (PM171E): 10 = 512 Kbytes
5.7 Extended Status Registers
Table 5-9 Extended Status Registers
Parameter
Register Size,
byte
Direction
Value range
Relay status
3452
2
R
see Table 5-10
Reserved
3453
2
R
Read as 0
Status inputs
3454
2
R
see Table 5-11
Setpoints status
3455
2
R
see Table 5-12
Log status
3456
2
R
see Table 5-13
Data log status
3457
2
R
see Table 5-14
Reserved 3458-
3473
2
R
Read as 0