Chapter 5 Setting Up the ETC II
Configuring Data Server
46
ETC II Network Communicator
9.
Enable the auto-reset option, if you wish the register to be automatically
cleared after it has been read:
Status register auto-reset: disabled
New [y/n]:
10.
Enable using Modbus Request 1 if you wish the register to be read as
coils:
Register type: holding
New [coil/holding]:
Data server
<
11.
Type
q
to quit the Data server menu.
Using PAS
Data Server Options
To enter the Setup dialog, select the ETC II site from the list box on the PAS
toolbar, and then select ETC II Setup from the Meter Setup menu.
The following table lists available Data server options.
Parameter
Options
Default
Description
Polling Interval
1-1000 min 1 min
Specifies the interval for
periodic polling connected
devices
Logging Interval, polls
0-1000,
0=logging
disabled
1
A non-zero interval enables
recording the acquired data
to the log file at predefined
intervals
Data Server Operations
Disabled,
Enabled
Disabled
Enables
Data
server
operations
Continuous Polling
Disabled,
Enabled
Disabled
If enabled, the Data server
polls devices continuously
without taking the polling
interval into account.
See
Data Server
in Chapter 3 for more information on using the Data server.
Real-Time Data Exchanges
To enter the Setup dialog, select the ETC II site from the list box on the PAS
toolbar, select ETC II Setup from the Meter Setup menu, and then click on
the Real-Time Data Exchanges tab.