CE SPECIFIC NOTICES (PAGE 7)
SAS™ EXTREME™ AUTO PROCESSOR
EMERGENCY STOP FUNCTION
To immediately stop the motion of this equipment:
1. Operator is to release all joystick button(s).
Additional secondary measures to immediately stop the motion include:
2. Moving excavator’s auxiliary hydraulic 3rd spool lever to neutral position
3. Turn off ignition key of excavator to shut off engine
All three emergency stop options stop flow of hydraulic fluid. See excavator manufac-
turer’s operator manual to identify proper controls & functions prior to use.
Even after emergency stop function is followed, there is residual stored hy-
draulic pressure in the system. See following:
THIS EQUIPMENT IS OPERATED BY HIGH PRESSURE HYDRAULICS.
Hydraulics are a stored power source and as such must be treated as energized at
all times. Be certain pressure has been relieved prior to handling, inspecting or per-
forming maintenance on this unit. Follow lockout tag out procedures and release all
stored energy before servicing equipment. Failure to release energy or disable hy-
draulic energy can result in serious injury or death. High pressure fluids can also dis-
charge at great velocity and cause injection into skin. Wear safety glasses and appro-
priate gloves while inspecting, operating and maintaining equipment.
STAY CLEAR
•
Do not lift persons with this equipment. Not intended to lift people
•
Always maintain a safe distance away from this equipment.
•
Do not go near or under this equipment or any object lifted by this
equipment. Failure to stay clear will result in injury or death.
•
Refer to and follow all additional safety information in excavator
manufacturer’s operator, safety and service manuals.
POWER FAILURE
In the event of electrical or hydraulic supply failure from the excavator occurs, the
equipment will stop further motion. Under normal circumstances the equipment is not
expected to drop a load.
The symbol at the left indicates the hydraulic controls on this
equipment are normally closed
. Thus without electrical power the gate valves are
closed, in essence halting further movement.
See excavator manufacturer’s oper-
ator manual to identify actual operation during power failure mode prior to use
.
SOUND
This equipment does not emit more than 70dba.
VIBRATIONS
This equipment does not transfer vibrations in excess of 2.5m/s2.
OPERATING TEMPERATURE
Equipment is best suited to operate in temperatures 0°C to 32°C (32°F to 90°F )
with minimum temperature –30°C (–23°F) and maximum temperature 65°C (150°F)
Summary of Contents for EXTREME AUTO PROCESSOR
Page 33: ......
Page 38: ...Assembly Assembly 0 1 Ra 3 2 m x4 2300028 2020 02 24 Indexator Rotator Systems AB 5...
Page 40: ...Assembly 0 1 Ra 3 2 m Option x2 XR400 I x1 2300028 2020 02 24 Indexator Rotator Systems AB 7...
Page 41: ...Assembly ISO 4406 1999 NAS 1638 18 16 13 7 8 Indexator Rotator Systems AB 2300028 2020 02 24...
Page 43: ...Assembly 24h 24h 24h STOP STOP 10 Indexator Rotator Systems AB 2300028 2020 02 24...
Page 62: ......
Page 63: ...4130 2300028 2020 02 24 3731...