Parameter Settings – Interface Port (Overview)
Intended Purpose

Configuration of the scale and its interface port; i.e., to meet individual requirements 
by selecting from among predefined parameters in the Setup menu.

o Factory settings

W

User-defined settings

Menü

1 and 8:

Refer to Menu Settings (Setup Menu)

5 Interface

5  1 Baud Rate

5  1  2

300 baud

5  1  3

600 baud

5  1  4

1,200 baud

5  1  5 o 2,400 baud
5  1  6

4,800 baud

5  1  7

9,600 baud

5  1  8

19,200 baud

5  2 Parity

5  2  3 o Odd 
5  2  4

Even

5  2  5

None

5  3 Number of Stop Bits

5  3  1 o 1 stop bit
5  3  2

2 stop bits

5  4 Handshake 

5  4  1

Software handshake

Mode

5  4  2 o Hardware handshake
5  4  3

None

5  5 Datenbits

5  5  1 o 7 data bits
5  5  2

8 data bits

6 Data Output   6  1 Print on request/

6  1  1

On request regardless

Auto print

of stability

6  1  2

On request after 
stability

6  1  3 o Auto print regardless

of stability

6  1  4

Auto print after 
stability

9 Reset Menu 

Refer to “Menu Settings (Setup Menu)" on page 10.

Menu level 1

Menu level 2

Menu level 3

Factory setting

Menu item

Summary of Contents for PMA600H

Page 1: ...98648 015 82 PMA Touc h up Installation Instructions Sartorius Model PMA600H PMA Touch Up Electronic Paint mixing Scales...

Page 2: ...on h key Clear Function 8 DC jack 9 Weight compartment 10 v key change menu item 11 q key start calibration 12 Display The following symbols are used in these instructions Indicates required steps Ind...

Page 3: ...YADAP RS 18 Default Settings 19 Specifications 20 Accessories 21 Declaration of Conformity 22 The PMA600H PMA Touch Up is a specially designed portable scale for use in paint mixing operations The sca...

Page 4: ...power supply the laws valid in your country must be observed If you have any ques tions please contact your supplier or Sartorius Customer Service for informa tion on the legal regulations applicable...

Page 5: ...ghing pan In use dust cover Scale Calibration weights AC adapter Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibration Make sure to read...

Page 6: ...tory requires the approval of a certified technician Insert the right angle plug into the DC jack 8 on the scale Plug the AC adapter into an electrical AC power outlet Inserting Batteries Note Batteri...

Page 7: ...in the illustration turn the leveling feet until the air bubble is centered within the circle of the level indicator In general several leveling steps will be necessary Calibration Weights Turn the t...

Page 8: ...ings q key Start calibration adjustment v key In the configuration menu and when calibrating adjusting scroll to select parameters h key Confirm parameter settings Configuration Calibration adjustment...

Page 9: ...etermining weight value Step Press Key Display 1 Turn on the scale e key 2 Zero tare the scale t key 3 Start calibration the defined calibration q key weight is displayed without a unit in this exampl...

Page 10: ...table conditions 1 1 2 o Stable conditions 1 1 3 Unstable conditions 1 1 4 Very unstable conditions 1 2 Application filter 1 2 1 Final readout 1 2 2 o Filling mode 1 3 Stability range 1 3 1 1 4 digit...

Page 11: ...requisites Unload scale were not met e g Zero tare with the t key Zero tare Do not calibrate until Zero is Weighing pan is loaded displayed appErr Too little weight or in the case Increase weight of a...

Page 12: ...MA is no longer ensured when There is visible damage to the AC adapter The AC adapter no longer functions properly The AC adapter has been stored for a relatively long period under unfavorable conditi...

Page 13: ...soiled in use dust cover and ensure that the adhesive points on the new cover properly adhere to the scale s surface The dust cover must be firmly attached Important Note If the dust cover does not ad...

Page 14: ...not members of the European Economic Area EEA or where no Sartorius affiliates subsidiaries dealers or distributors are located please contact your local authorities or a com mercial disposal operato...

Page 15: ...n the balance scale on its side To avoid damaging the weighing system do not turn the balance scale over so that it rests on the weighing pan load plate Push out the panel on the bottom of the balance...

Page 16: ...he equipment supplied with the USB interface adapter includes a CD contain ing the software drivers you need to set up a virtual interface on your computer Software Driver and Installation Guides The...

Page 17: ...tions e g only COM1 2 3 4 you may have to assign one of these port numbers to the new virtual port Open the settings for the USB serial port in Windows START My Computer Control Panel System Hardware...

Page 18: ...und GND Pin 6 Connected to pin 8 Pin 7 Not connected Pin 8 Data terminal ready DTR Pin 9 Not connected Parameter Settings Menu Navigation Purpose Configuring the balance scale and its data interface t...

Page 19: ...800 baud 5 1 7 9 600 baud 5 1 8 19 200 baud 5 2 Parity 5 2 3 o Odd 5 2 4 Even 5 2 5 None 5 3 Number of Stop Bits 5 3 1 o 1 stop bit 5 3 2 2 stop bits 5 4 Handshake 5 4 1 Software handshake Mode 5 4 2...

Page 20: ...C 10 to 40 273 to 303 K 50 to 86 F Weighing pan mm 140 127 Net weight approx kg 1 3 Calibration weights 2 g 100 Class F1 in the weight compartment Power consumption average W 0 8 Interface port option...

Page 21: ...ith cable 2 m YADAP USB Carrying case Upon request Anti theft locking device LC 1 Calibration weights universal for weight compartment in scale 100 g F1 69V0007 Weighing pan square Upon request Feet S...

Page 22: ...22...

Page 23: ...ettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius The status of the informat...

Reviews: