background image

 

 

DM SERIES 

 

HIGH PRECISION WEIGHING SCALE 

   

 

OPERATION MANUAL

 

 
 

 

PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE 

ATTEMPT TO OPERATE THIS SCALE 

 
 

 

 
 
 
 
 
 
 
 
 

 
 

V118  June  2012 

 

Specifications subject to change without prior notice 

Summary of Contents for DM-10K

Page 1: ...DM SERIES HIGH PRECISION WEIGHING SCALE OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THIS SCALE V118 June 2012 Specifications subject to change without prior notice ...

Page 2: ......

Page 3: ...S 4 GETTING STARTED 5 INITIAL SETUP 6 INSTRUCTION FOR USE 7 RS232 DATA OUTPUT MODE 8 TICKET RECEIPT PRINTING 9 LABEL PRINTING LP 50 or CPOMPATIBLE 10 BATTERY POWER AND RECHARGING 11 ERROR CODES 12 DAILY CARE AND MAINTENANCE Appendix A BI DIRECTIONAL COMMUNICATION COMMANDS ...

Page 4: ... legal for trade only when it is sealed and or stamped and bearing a serial number Do not attempt to break the seal or stamp affixed to this scale or remove the serial number Contact your dealer for more information and after sales service For most accurate weighing result do not use the unit in where or when the environment condition falls beyond as those listed on SPECIFICATIONS Do not attempt t...

Page 5: ... 5000 10000 0 1 0 2 DM 20K 20000 Nil 0 1 Nil DM 20KD 10000 20000 0 1 0 2 Weight Units kg g lb Weight Unit Conversation Supports Single Range Models only Tare Range Max Subtractive Tare Platter 220 x 290mm all Stainless Steel Dual Power Source Built in Rechargeable Battery and DC External Power Adaptor Operation Environment 15 35o C Non condensed R H 85 Specifications subject to change prior to not...

Page 6: ...3 KEYS DISPLAY AND CONNECTIONS ...

Page 7: ...o memory manually 6 ZERO KEY Press this key to set weight displayed to zero when an empty scale has drifted away from a true zero reading 7 TARE KEY Press this key to tare off the weight of a container 8 FUNCTION KEY Press this key to shift between percentage piece count and animal2 mode 9 CHECK FUNCTION Press this key to start check weighing function and to enter value for HI and LO limit 10 CE K...

Page 8: ...o function assigned 16 M INDICATOR Visible when the total accumulated weight value is being displayed 17 BATTERY POWER LEVEL INDICATOR Visible to show This scale is being powered by the built in rechargeable battery Remaining battery level 18 HOLD INDICATOR When under animal mode Visible when weight reading being displayed is a frozen value 3 This indicator will not appear when this instrument is ...

Page 9: ...ight detected is in stable condition 23 ZERO INDICATOR Visible when this scale is at true zero weight status 24 CAPACITY TRACK BAR The ratio increment 10 of applied remaining weighing capacities are shown here 25 WEIGHT UNITS AND FUNCTIONS Percentage when in Percentage Mode in function kg kilogram PCS Pieces Piece Count Mode in function kg PCS and g PCS Weight per piece Piece Count Mode in functio...

Page 10: ...Y Press this key to turn this scale on or off B DC JACK INPUT External power adaptor is plugged in here Output requirements of the power adaptor DC9 12V 800mA Polarity Any kind C RS232 COMPORT DB9 RS232 communication comport ...

Page 11: ...ration or extremes of temperature before or after installation 4 1 BUILT IN RECHARGEABLE BATTERY This scale is equipped with a built in rechargeable battery Before first time use recharge it for at least 8 hours to ensure the best battery performance 4 2 POWER ADAPTOR Before plugging in the power adaptor check and make sure the input voltage of the adaptor matches with output voltage of the electr...

Page 12: ...t all preferred operation parameters according to 5 4 INTERNAL FUNCTION TABLE NOTE 1 F1 F26 are accessible without restriction 2 F60 F66 are restricted functions which may request a password or hardware key to access 3 F80 F99 are restricted functions which may request a password or hardware key to access These functions are usually for dealer and authorized personnel only and all settings these f...

Page 13: ...ow in internal function e Quick access to a function number Press 1 to go to F10 Press 2 to go to F20 Press 6 to go to F60 for dealer and authorized personnel only Press 8 to go to F80 for dealer and authorized personnel only Press 9 to go to F99 for dealer and authorized personnel only Press 0 to go to F1 5 3 KEY FUNCTION DURING INTERNAL FUNCTION MODE M Enter save and return ZERO Quit without sav...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...gently Excessive force applied to platform may cause damages to the weight sensor c The weight of the object is displayed automatically d It is a good practice to remove all loads from platform after weighing It will prolong the life of the weight sensor 6 3 ABOUT WEIGH UNIT CONVERSION The default weight unit is kg Depends on the internal settings this scale supports also g and lb 6 3 1 Conversion...

Page 20: ... from platform b Make sure that the ZERO INDICATOR is on If not press ZERO c Place container on platform d Press TARE e NET INDICATOR appears to indicator tare is in effect and weight displayed display is net weight Refer to SPECIFICATIONS for maximum tare range f To cancel tare effect remove all loads from platform and press TARE g NET INDICATOR disappears GROSS INDICATOR appears to indicator tar...

Page 21: ...ad on the platform 6 4 4 Preset Tare F63 A pre determined tare weight can be entered via keyboard To enable this function set F63 to ON then set also F12 to OFF During normal operation press 0 then followed by the pre determined tare weight through numeric keys and press M to enter To cancel preset tare effect remove all loads from platform then press TARE NOTE 1 The pre determined tare weight ent...

Page 22: ...all total accumulated weight from memory b After MR is pressed This scale displays n n means the number of transactions accumulated follow by the total accumulated weight stored in memory c At this point Press ZERO to quit or Press ZERO followed by CE to clear memory and return operation M INDICATOR disappear to indicate no data is stored in memory 6 6 FUNCTION MODES This scale is equipped with th...

Page 23: ...s functions until Piece Count CoUnt appears d Press M to enter e Default16 sample size and PCS INDICATOR appear f This scale is now in Piece Count Function g Refer to 6 8 1 for subsequent operation procedures 6 8 1 Sampling Process a Put samples with same quantity on platform then press M Should a different sample size is required enter the quantity of the sample size through the numeric keys17 b ...

Page 24: ... PCS 6 8 3 To quit Piece Count Function19 Refer to 6 7 2 on how to quit and back to weighing function 6 9 PERCENTAGE FUNCTION20 Follow the below steps to enter Percentage Function a Refer to 6 3 on how to select the desired weight unit b If a container is used place it onto the platform and press TARE c If a reference mass mass value which is considered as 100 is available apply it on platform NOT...

Page 25: ...Lt value applied Select the preferred filter value25 by pressing FUNC or UNIT key 3 filer values are available FLt 1 Fast FLt 2 Normal For human weighing select this parameter FLt 3 Slow f Display the last weight release variation value rE applied Under the animal weighing function this scale will hold a weight result until the pre defined weight release variation value is achieved g Select the pr...

Page 26: ...up of animals The result obtained will be displayed HOLD INDICATOR appears to indicate that this weight value is being held frozen 26 c Get other animals on platform in case more animals have to be weight in the same transaction d An updated weight will be calculated and displayed27 as above step b 6 10 2 To Update Weight Value Manually To update the weight reading manually press ZERO 6 10 3 To Qu...

Page 27: ...ction is now enabled The check is result is shown by one of the HI OK LO symbols g The same result will be sent to the relay module if ordered together with the buzzer signal NOTE 1 For normal comparison set both HI and LO limits 2 To check only if result is lower than or equal to LO result LO set HI limit 0 3 To check only if result is higher than or equal to HI result HI set LO limit 0 4 To chec...

Page 28: ...d and used to start stop of the outflow device Refer to DIAGRAM INFLOW OUTFLOW for more information of this control logic 6 14 ABOUT NEAR ZERO VALUE F26 Nero zero value is useful for both dynamic weighing applications It is used to avoid false LO signal when a load is approaching and leaving the weighing platform HI OK LO comparison will only start when weight reading exceeds the near zero value e...

Page 29: ...6 15 TO QUIT CHECKWEIGHING MODE To quit stop checkweighing mode set both HI and LO limits to zero DIAGRAM INFLOW OUTFLOW DIAGRAM NEAR ZERO VALUE ...

Page 30: ...nsmitted in ASCII code Data format is listed on below table DATA BIT DESCRIPTION 1 2 MOTION STATUS US UNSTABLE ST STABLE 3 COMMA SEPARATION 4 5 NET GROSS NT NET WEIGHT GS GROSS WEIGHT 6 SIGN Sign of weight reading Positive space Negative minus 7 13 WEIGHT VALUE 7 digits weight value including location of decimal point If there is no decimal point then the first character space 14 COMMA SEPARATION ...

Page 31: ... 1 1 Weighing function 7 lines will be transmitted as below 1 Time of print 2 Date of printing 3 Transaction sequent number if this transaction is accumulated to memory 4 Net weight 5 Tare Weight 6 Gross Weight 7 Total accumulated net weight if accumulation function is in effect Sample 1 TIME 15 21 00 DATE 14 04 2009 NO 1 First transaction added to memory NET 500 0kg TARE 0 0kg GROSS 500 0kg TOTAL...

Page 32: ... NO 3 Third transaction added to memory NET 500 0kg TARE 200 0kg GROSS 700 0kg TOTAL 1200 0kg Total accumulated net weight 8 1 1 2 Piece count function 5 lines will be transmitted as below 1 Time of print 2 Date of printing 3 Net weight 4 Unit weight average piece weight 5 Count quantity in terms of number of pieces Sample 1 TIME 15 30 44 DATE 14 04 2009 NET 300 0kg UNIT W 599 949 g COUNT 500PCS ...

Page 33: ... of printing 3 Net weight 4 Weight value of reference 100 mass 5 Count quantity in terms of number of pieces Sample 1 TIME 15 39 13 DATE 14 04 2009 NET 699 0kg REF 200 0kg PERCENT 350 00 8 1 1 4 Animal weighing function 3 lines will be transmitted as below 1 Time of print 2 Date of printing 3 Weight Net being held Sample 1 TIME 16 33 42 DATE 14 04 2009 HOLD W 496 0kg ...

Page 34: ...lated to memory 4 Net weight 5 Tare Weight 6 Gross Weight 7 Total accumulated net weight when accumulation function is in effect 8 One blank line 9 One blank line 10 HI limit 11 LO limit 12 Comparison result Sample 1 TIME 17 39 05 DATE 14 04 2009 NO 5 NET 200 0kg TARE 0 0kg GROSS 200 0kg TOTAL 3799 0kg HIGH 2000 0kg LOW 500 0kg BELOW LIMIT 39 Standard output print format of checkweighing mode does...

Page 35: ...ME 17 39 34 DATE 14 04 2009 NO 7 NET 2500 0kg TARE 200 0kg GROSS 2700 0kg TOTAL 6799 0kg HIGH 2000 0kg LOW 500 0kg ABOVE LIMIT 8 1 2 2 Piece count function with checkweighing 10 lines will be transmitted as below 1 Time of print 2 Date of printing 3 Net weight 4 Unit weight average piece weight 5 Count quantity in terms of number of pieces ...

Page 36: ... g COUNT 499PCS HIGH 1000PCS LOW 500PSS BELOW LIMIT 8 1 2 3 Percentage function with checkweighing 10 lines will be transmitted as below 1 Time of print 2 Date of printing 3 Net weight 4 Weight value of reference 100 mass 5 Count quantity in terms of number of pieces 6 One blank line 7 One blank line 8 HI limit 9 LO limit 10 Comparison result ...

Page 37: ...ore detail 8 2 1 To Edit Custom Print Output Format Follow the below steps to create custom printout a Go to internal function and select the desired function number to edit b Select CUSTOM and press M c This instrument displays Line 1 and the last variant or command see 8 2 2 for details stored d Press M to confirm or select other variant or command by press 40 When F18 is either set to MODE 3 41...

Page 38: ...ctions NOTE 1 Disregarding the total number of lines the last line must be End 2 This instrument will automatically add End on line number 15th for Weighing Piece Count and Percentage function and on line number 10th for animal weighing function 8 2 2 Print Output Format Variants Table SYMBOL DESCRIPTION End Edit finished Cr LF Goto next line dAtE Date of printing tiME Time of print nEt Net weight...

Page 39: ...when accumulation function is in effect SiGn Signature 8 2 3 Edit Sample for Custom Print Output Format PRINT CONTENT Line No Select TIME 17 39 05 1 tiME DATE 14 04 2009 2 dAtE NET 200 0kg 3 nEt TARE 0 0kg 4 tArE GROSS 200 0kg 5 GroSS Blank line 6 Cr LF Signature 7 SiGn 8 End ...

Page 40: ...king modes on the same label 2 Do not print any labels of non current working mode This will retrieve wrong data of non current working mode 3 Print only label data when the same working mode is in operation 4 Do not combine data of various working modes on same label This will retrieve wrong data of non current working mode 9 1 LABEL FORMAT GROUPS AND LABEL FILE NAMES 2 label format groups are av...

Page 41: ... in printer for this format group 1 must have a file name of BB1 dlb BB2 dlb BB3 dlb BB4 dlb and BB5 dlb In this instrument 5 printout selections are available in format group 2 For 2 1 Select this to print label file BB1 dlb stored in printer For 2 2 Select this to print label file BB2 dlb stored in printer For 2 3 Select this to print label file BB3 dlb stored in printer For 2 4 Select this to p...

Page 42: ...ence mass 100 Percentage 9 X Percentage value Percentage 10 Y Weight Hold Animal weighing Animal Weighing 9 Note A Good for all except animal weighing mode 46 Commands must be in capital letter 47 All means the information is good for all working modes 48 Each working mode has its own Hi Limit format weight for weighing mode pieces for counting mode for percentage mode If Hi Limit has to be printe...

Page 43: ...9 2 2 Label Programming Sample 9 2 2 1 Sample Label of Current Transaction For 1 9 2 2 2 Sample Label of Totalized Data For 2 ...

Page 44: ...chargeable battery is at low voltage status It is recommended to recharge as soon as possible To protect the built in rechargeable battery this scale will be powered off automatically when battery is at extremely low level If this is the case do not attempt to power this scale on Recharge this scale immediately Fail to do so may cause unrecoverable damages to the built in rechargeable battery Batt...

Page 45: ...oad cell signal detected Err 6 Tare operation error Err 7 Logic error HI limit set is lower than LO limit and HI is not 0 Err 8 Logic error LO limit is higher than HI limit and HI is not 0 Err 9 ERROR IN PERCENTAGE FUNCTION INPUT VALUE 0 or less than 50e oL Overload Gross weight is more than Max plus 9d UndEr Negative Weight values exceeds display range Negative Tare value exceeds display range ...

Page 46: ...ial acetone volatile solvent thinner or alcohol for cleaning Verify the accuracy of this scale periodically Re calibrate if necessary In some countries calibration requires authorized qualified agent Contact your dealer for more information Store this scale in a dry and clean place Recharge battery before and every 2 months during long time storage ...

Page 47: ... standard communication programs like Hyper Terminal which comes with most of the Windows operating system in computer A Direct Control Commands50 F18 Mode 1 2 and 4 Equivalent direct control commands for each of the key on keyboard from computer are shown below 50 Direct Control Commands to be transmitted to this instrument are not case sensitive ...

Page 48: ...ent working mode B B 1 Information Request Commands Table Commands51 Operation Data Working Mode52 Data Length J Current status weight and tare weight values All 24 K Date of printing All 10 L Time of print All 8 M No of accumulated transaction Normal Weighing 7 N Total accumulated weight when accumulation function is in effect Normal Weighing 9 O Net weight All 10 P Tare weight All 10 Q Gross wei...

Page 49: ... instrument is illustrated on below table Commands Data example and format Description J ST NT 123 567 123 567 kg 2 digits motion status ST stable US unstable 1 digit comma separation 2 digits Net Gross NT Net GS Gross 1 comma separation 1 digit sign Positive space Negative minus 7 digits weight value including decimal point If there is no decimal point then the first character space 1 digit comma...

Page 50: ... decimal point then the first character space 2 digits weight unit P 123 567kg 123 567kg P23 567kg 1 sign of weight reading Positive space Negative minus 7 digits tare weight value including decimal point If there is no decimal point then the first character space For preset tare the first digits P 2 digits weight unit Q 123 567kg 123 567kg 1 sign of weight reading Positive space Negative minus 7 ...

Page 51: ... mode T ACCEPT BELOW LIMIT ABOVE LIMIT 6 digits ACCEPT 11 digits for BELOW LIMIT and ABOVE LIMIT U 10000PCS 5000PCS 1 sign of weight reading Positive space Negative minus 1 digit space 6 digits number of pieces 3 digits PCS V 123 567 g 7 digits unit piece weight value including decimal point If there is no decimal point then the first character space 2 digits weight unit W 123 567kg 7 digits refer...

Page 52: ...g decimal point If there is no decimal point then the first character space 1 digit space 1 digit Y 123 567kg 7 digits hold weight value including decimal point If there is no decimal point then the first character space 2 digits weight unit ...

Reviews: