Care and Maintenance

Cleaning

!

Unplug the AC adapter from the wall 
outlet (mains supply). If you have a data
cable connected to the interface, unplug
it from the scale.

!

Do not use caustic agents, concentrated
acids or pure alcohol.

$

Make sure that no liquid enters the scale
housing.

$

Clean the scale using either a brush or a
soft, dry, lint-free cloth.

Storage and Shipping Conditions

$

To ensure safe shipment, your scale has
been packaged using environmentally-
friendly materials. You should retain
these materials in case you need to pack-
age your scale for storage or return 
shipment.

$

Storage temperature: –20°C to +75°C

$

Permissible moisture level for storage of
the packaged scale: 90% max.

$

Read and follow the instructions given in
the section entitled “Safety Inspection.”

Safety Inspection

Safe operation of the PMA is no longer
ensured when:

– There is visible damage to the AC adapter
– The AC adapter no longer functions

properly

– The AC adapter has been stored for a 

relatively long period under unfavorable
conditions

– The equipment has been exposed to

rough handling during shipment

§

Observe the warnings and safety 
precautions in this manual
Notify your nearest Sartorius Service 
Center or the International Technical
Support Unit based in Goettingen, 
Germany. Maintenance and repair work
may only be performed by service techni-
cians who are authorized by Sartorius and
who have access to the required service
and maintenance manuals, and have
attended the relevant service training
courses.

!

The seals affixed to this equipment indi-
cate that only authorized service techni-
cians are allowed to open the equipment
and perform maintenance work so that
safe and trouble-free operation of the
equipment is ensured and the warranty
remains in effect.

Replacing the In-Use Dust Cover

§

Remove the weighing pan

PMA.Touc

h up

Summary of Contents for PMA600H

Page 1: ...98648 015 82 PMA Touc h up Installation Instructions Sartorius Model PMA600H PMA Touch Up Electronic Paint mixing Scales...

Page 2: ...on h key Clear Function 8 DC jack 9 Weight compartment 10 v key change menu item 11 q key start calibration 12 Display The following symbols are used in these instructions Indicates required steps Ind...

Page 3: ...YADAP RS 18 Default Settings 19 Specifications 20 Accessories 21 Declaration of Conformity 22 The PMA600H PMA Touch Up is a specially designed portable scale for use in paint mixing operations The sca...

Page 4: ...power supply the laws valid in your country must be observed If you have any ques tions please contact your supplier or Sartorius Customer Service for informa tion on the legal regulations applicable...

Page 5: ...ghing pan In use dust cover Scale Calibration weights AC adapter Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibration Make sure to read...

Page 6: ...tory requires the approval of a certified technician Insert the right angle plug into the DC jack 8 on the scale Plug the AC adapter into an electrical AC power outlet Inserting Batteries Note Batteri...

Page 7: ...in the illustration turn the leveling feet until the air bubble is centered within the circle of the level indicator In general several leveling steps will be necessary Calibration Weights Turn the t...

Page 8: ...ings q key Start calibration adjustment v key In the configuration menu and when calibrating adjusting scroll to select parameters h key Confirm parameter settings Configuration Calibration adjustment...

Page 9: ...etermining weight value Step Press Key Display 1 Turn on the scale e key 2 Zero tare the scale t key 3 Start calibration the defined calibration q key weight is displayed without a unit in this exampl...

Page 10: ...table conditions 1 1 2 o Stable conditions 1 1 3 Unstable conditions 1 1 4 Very unstable conditions 1 2 Application filter 1 2 1 Final readout 1 2 2 o Filling mode 1 3 Stability range 1 3 1 1 4 digit...

Page 11: ...requisites Unload scale were not met e g Zero tare with the t key Zero tare Do not calibrate until Zero is Weighing pan is loaded displayed appErr Too little weight or in the case Increase weight of a...

Page 12: ...MA is no longer ensured when There is visible damage to the AC adapter The AC adapter no longer functions properly The AC adapter has been stored for a relatively long period under unfavorable conditi...

Page 13: ...soiled in use dust cover and ensure that the adhesive points on the new cover properly adhere to the scale s surface The dust cover must be firmly attached Important Note If the dust cover does not ad...

Page 14: ...not members of the European Economic Area EEA or where no Sartorius affiliates subsidiaries dealers or distributors are located please contact your local authorities or a com mercial disposal operato...

Page 15: ...n the balance scale on its side To avoid damaging the weighing system do not turn the balance scale over so that it rests on the weighing pan load plate Push out the panel on the bottom of the balance...

Page 16: ...he equipment supplied with the USB interface adapter includes a CD contain ing the software drivers you need to set up a virtual interface on your computer Software Driver and Installation Guides The...

Page 17: ...tions e g only COM1 2 3 4 you may have to assign one of these port numbers to the new virtual port Open the settings for the USB serial port in Windows START My Computer Control Panel System Hardware...

Page 18: ...und GND Pin 6 Connected to pin 8 Pin 7 Not connected Pin 8 Data terminal ready DTR Pin 9 Not connected Parameter Settings Menu Navigation Purpose Configuring the balance scale and its data interface t...

Page 19: ...800 baud 5 1 7 9 600 baud 5 1 8 19 200 baud 5 2 Parity 5 2 3 o Odd 5 2 4 Even 5 2 5 None 5 3 Number of Stop Bits 5 3 1 o 1 stop bit 5 3 2 2 stop bits 5 4 Handshake 5 4 1 Software handshake Mode 5 4 2...

Page 20: ...C 10 to 40 273 to 303 K 50 to 86 F Weighing pan mm 140 127 Net weight approx kg 1 3 Calibration weights 2 g 100 Class F1 in the weight compartment Power consumption average W 0 8 Interface port option...

Page 21: ...ith cable 2 m YADAP USB Carrying case Upon request Anti theft locking device LC 1 Calibration weights universal for weight compartment in scale 100 g F1 69V0007 Weighing pan square Upon request Feet S...

Page 22: ...22...

Page 23: ...ettingen Germany All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius The status of the informat...

Reviews: