35
■
HEATING
Model Number :
STW0633H2 / 0634H2
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
265V, 1-phase 60Hz
Rating conditions
Running amps.
A
0.09
0.32
1.79
2.2
Power input
kW
0.025
0.085
0.460
0.57
Full load conditions
Running amps.
A
0.09
0.32
2.19
2.6
Power input
kW
0.025
0.085
0.570
0.68
Model Number :
STW0933H2 / 0934H2
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
265V, 1-phase 60Hz
Rating conditions
Running amps.
A
0.09
0.32
2.49
2.9
Power input
kW
0.025
0.085
0.630
0.74
Full load conditions
Running amps.
A
0.09
0.32
3.29
3.7
Power input
kW
0.025
0.085
0.830
0.94
Model Number :
STW1233H2 / 1234H2 / 1235H2
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
265V, 1-phase 60Hz
Rating conditions
Running amps.
A
0.15
0.38
3.37
3.9
Power input
kW
0.040
0.100
0.880
1.02
Full load conditions
Running amps.
A
0.15
0.38
4.47
5.0
Power input
kW
0.040
0.100
1.170
1.31
Model Number :
STW1534H2 /1535H2
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
265V, 1-phase 60Hz
Rating conditions
Running amps.
A
0.15
0.38
4.67
5.2
Power input
kW
0.040
0.100
1.210
1.35
Full load conditions
Running amps.
A
0.15
0.38
6.17
6.7
Power input
kW
0.040
0.100
1.620
1.76
Rating Conditions
: Indoor Air Temperature 70°F (21.1°C) D.B.
Outdoor Air Temperature 47F (8.3°C) D.B. / 43°F (6.1°C) W.B.
Full Load Conditions : Indoor Air Temperature 80°F (26.7°C) D.B.
Outdoor Air Temperature 75°F (23.9°C) D.B. / 65°F (18.3°C) W.B.