10. Diagnosis of Failure with LED indication
This projector provides a function which is to specify an abnormal place/part simply by indicating the LEDs on the
cabinet. Connect the AC cord and turn on the projector with the mains switch, and then check the LED indication.
LAMP
REPLACE1
WARMING
TEMP
WARNING
FILTER
LAMP
READY
SHUTTER
LAMP
REPLACE2
ERROR
CONDITION
❂
●
●
Temperature error
Inside temperature is abnormally high
❂
●
❂
Lamp failure
Lamp1 or 2 cover is not placed correctly
❂
●
●
Lamp failure
Lamp failure on Lamp1
●
●
❂
Lamp failure
Lamp failure on Lamp2
❂
●
●
❂
Lamp failure
One lamp is different from the other
❂
Filter failure
Air filter is not placed correctly
●
●
❂
Shutter failure
Does not operate shutter properly
❂
❂
❂
●
❂
❂
❂
Power failure
Failure on power supply or fans operation
Safety protection
Operates safety protection circuit
No Power
●
...... LED lightning
❂
...... LED blinking
Chassis Description & Troubleshooting
Summary of Contents for PLC-XF60
Page 104: ... 104 IC Block Diagrams TC4052BFT Selector IC9005 TB1274AF RGB Matrix IC3101 ...
Page 105: ... 105 IC Block Diagrams TC90A69F PAL Y C Separator IC2101 TE7780 I O Expander IC4801 IC4802 ...
Page 106: ... 106 IC Block Diagrams MAS1390 G Sensor IC5711 NJW1141 Audio Selector Controller IC9501 ...
Page 157: ...MM7 XF6000 157 Mechanical Parts List L15 R G Optical Filter WV Optical Filter WV S05 S05 ...
Page 158: ...MM7 XF6000 158 Mechanical Parts List 1 2 0 5 L03 Integrator In Integrator In ...
Page 160: ...MM7 XF6000 160 Mechanical Parts List L09 Mirror R Mirror R S05 S05 ...
Page 161: ...MM7 XF6000 161 Mechanical Parts List L13 Optical Filter R Optical Filter R ...
Page 162: ...MM7 XF6000 162 Mechanical Parts List 162 Relay lens Out L08 Relay Lens Out ...
Page 165: ...MM7 XF6000 165 Mechanical Parts List ...
Page 166: ... MM7A Oct 2004 BB 400 Printed in Japan SANYO Electric Co Ltd ...