- 50 -
Electrical Adjustments
Group
No.
Item
Function
Range
Initial Value
0
Hi-Land SW
0:Normal Mode1: High-land Mode (Fan max speed continuously)
0 ~ 1
0
1
Not used
Not used
--
2
ANZEN FAN Control Fix SW
0:Normal 1:Normal Min2:Normal Max3:Eco Min4:Eco Max
142
Fan Parameter Setting
0
FAN_TEMP_A_WARNING
Temperature A to judge Abnormal Temp. (memorized) Outside
43
1
FAN_TEMP_B_WARNING
Temperature B to judge Abnormal Temp. (momorized) on Panel
60
2
FAN_TEMP_C_WARNING
Voltage C to judge Abnormal Temp. (momorized) arround Panel
55
3
Not used
--
4
Not used
--
5
Control Switch All
0:Auto-control all of FANs 1: Manual Control all of FANs
0 / 1
0
6
FAN A Manual Out
Fan voltage in the manual mode
0~2000
7
FAN B Manual Out
Voltage= Value/100
0~2000
8
FAN C Manual Out
Effective FAN_CONTROL_SW=1
0~2000
9
FAN D1 Manual Out
Step in 10, 0.1V
0~2000
10
FAN D2 Manual Out
0~2000
11
FAN EManual Out
0~2000
12
Temp Source Range High
High and Low control limit value at Temp. sensor A
30 ~ 100
41
13
Temp Source Range Low
Temp. =Value/10
0 ~ 100
27
14
Temp Fan-Out Range High
High and Low Fan voltage value at Temp. sensor A
0~2000
1400
15
Temp Fan-Out Range Low
Voltage = Value/100
0~2000
0
16
Not used
--
17
Not used
--
18
Not used
--
19
Not used
--
20
Presss Source Range Low
High and Low control limit value at Atmosphere Sensor
0~1024
515
21
Presss Source Range High
Note: Low is Fan add Max point accually
0~1024
745
22
Press FanAdd Range High
High and Low Fan Voltage value at Atmosphere Sensor
0~255
35
23
Press FanAdd Range Low
Voltage = Value/100
0~255
0
24
Ceil-Add
Additional Voltage at Ceiling use Voltage = Value/100
0~2000
0
149
PJ Filter Reset Times
0
FILTER_CLR_CNT
Reset times of the airfilter timer counter
150
Shippment Setting
0
Shippment Setting
All of settings are set to default when the value changes to 10
0 ~ 10
0
160
Shootout
0
Switch
0:Off, 1:On
0 / 1
0
170
Smoke Resist Fan
0
Smoke Fan1 Speed Monitor
Fan speed 1monitor of Smoke resister
---
---
1
Smoke Fan2 Speed Monitor
Fan speed 2monitor of Smoke resister
---
---
2
Smoke Fan Speed Control
Set speed for Smoke resister 0:Normal / 1:MAX fixed / 2:USER(setting
enable on 170-3)
0 ~ 2
0
3
Smoke Fan Speed Setting
Set speed of user setting for Smoke resister (Effective only 170-2 is
2 (USER)
0 ~ 50
20
4
Smoke fan Setting Speed Monitor
Monitor at current setting
--
--
5
Smoke Fan Speed Mini. Duty Value
Display Duty value at minimum temp. for Auto-Fan Control
20
6
Smoke Fan Speed Max. Duty Value
Display Duty value at maximum temp. for Auto-Fan Control
50
7
Smoke Fan Speed Min. Temp.
Sets minimum temp. for Auto-Fan Control
0 ~ 99
27
8
Smoke Fan Speed Max. Temp.
Sets maximum temp. for Auto-Fan Control
0 ~ 99
40
9
Smoke Box Time Counter Reset Times
Reset times of the Smoke Box time counter
10
Smoke Box use time
Accuurated use time of the Smoke Box
11
Smoke Box Version
“9999” upper 2 digits for Main version, lower for Sub version
171
Smoke Box Fan: Calibration
0
Execute calibration of Fan Speed
1: Execute Calibration, 2: Complete, -1: Error
-1 ~ 2
0
1
Smoke Fan1: result Offset
Smoke Fan1: result of cloggled filter calibration, Offset value
2
Smoke Fan1: result Min.
Smoke Fan1: result of cloggled filter calibration, Min. Fan Speed
3
Smoke Fan1: result Max.
Smoke Fan1: result of cloggled filter calibration, Max. Fan Speed
4
Smoke Fan2: result Offset
Smoke Fan2: result of cloggled filter calibration, Offset value
5
Smoke Fan2: result Min.
Smoke Fan2: result of cloggled filter calibration, Min. Fan Speed
6
Smoke Fan2: result Max.
Smoke Fan2: result of cloggled filter calibration, Max. Fan Speed
7
Smoke Fan Calibration OK Times
Succeed times of the Smoke Box Calibration
8
Air Pressure at Smoke Filter Calibration
Air Pressure at Smoke Filter Calibration
180
DDC Setting
0
HDCP EDID Data Setting
0:EDID Data for DVI / 1:EDID Data for HDCP
0 / 1
0
190
Mecha Shutter
0
Warming up option
0:Warming up Enable1:Warming up Disable
0 / 1
0
200
Panel Adjustment PC [Lamp ALL]
XGA[SXGA]
0
A03(IC571)V1G
DAC Video Center G L (IC571 16pin)
0 ~ 255
84 [80]
1
A01(IC571)V1R
DAC Video Center R L (IC571 14pin)
0 ~ 255
84 [80]
2
A05(IC571)V1B
DAC Video Center B L (IC571 18pin)
0 ~ 255
84 [80]
3
A04(IC571)V2G
DAC Video Center G H (IC571 17pin)
0 ~ 255
144 [143]
Summary of Contents for PLC-XF60
Page 104: ... 104 IC Block Diagrams TC4052BFT Selector IC9005 TB1274AF RGB Matrix IC3101 ...
Page 105: ... 105 IC Block Diagrams TC90A69F PAL Y C Separator IC2101 TE7780 I O Expander IC4801 IC4802 ...
Page 106: ... 106 IC Block Diagrams MAS1390 G Sensor IC5711 NJW1141 Audio Selector Controller IC9501 ...
Page 157: ...MM7 XF6000 157 Mechanical Parts List L15 R G Optical Filter WV Optical Filter WV S05 S05 ...
Page 158: ...MM7 XF6000 158 Mechanical Parts List 1 2 0 5 L03 Integrator In Integrator In ...
Page 160: ...MM7 XF6000 160 Mechanical Parts List L09 Mirror R Mirror R S05 S05 ...
Page 161: ...MM7 XF6000 161 Mechanical Parts List L13 Optical Filter R Optical Filter R ...
Page 162: ...MM7 XF6000 162 Mechanical Parts List 162 Relay lens Out L08 Relay Lens Out ...
Page 165: ...MM7 XF6000 165 Mechanical Parts List ...
Page 166: ... MM7A Oct 2004 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 170: ...Diagrams Drawings MM7 XF6000 ...