- 74 -
6. Fan Control
The Fan drive power supplies "FAN_A", "FAN_B", "FAN_C", "FAN_D1", "FAN_D2", "FAN_E" and "16V_M" are gener-
ated in the POWER(DC) board. Each power supply drives fans as follow;
FAN_A ...............Fan FN901, FN902, FN903 for LCD panel cooling and fan FN904 for PBS cooling
FAN_B ............... Fan FN907 for POWER 1,2(AC) board cooling and fan FN905 for main exhaust
FAN_C ..............Fan FN908 for Lamp2 cooling and fan FN909 for lamp exhaust
FAN_D1 ............Fan FN910 for Lamp1 cooling
FAN_D2 ............Fan FN914 for Lamp2 cooling
FAN_E ...............Fan FN911 for lamp ballast unit cooling
16V_M ...............Fan FN913 for mechanical shutter cooling
When an abnormality occurs on any one of the fans FN901 to FN905, FN907, FN908, FN910, FN911 or FN914, each
fan lock signal "FAN_PF" is sent to the detection circuit on the POWER(DC) board. The POWER(DC) board sends
the abnormality to the IC801<CPU> via the IIC bus. When the abnormality occurs on the fans FN909 or FN913, each
fan lock signal "FAN_PF" is sent to IC4714<INPUT EXPANDER>. IC4714 sends the abnormality to the IC801 via the
parallel bus.
Temperature Sensors (IC8821, IC8841)
The temperature sensors IC8821 on the LCD DRIVE board and IC8841 on the TEMP. SENS. board measure sur-
rounding temperature and sends data to IC801<CPU> via the IIC bus. IC801 controls proper fan spinning speed
based upon this temperature data. Also, when the temperature rises over a specified value, IC801 judges that there
is abnormal internal temperature and turns off the projector.
Atmosphere Sensor (IC4895)
The deviation of the atmosphere due to high altitude difference changes airflow of the cooling fan. IC4895 measures
the atmosphere at the setting place of the projector, and sends data to the IC801<CPU> via the IC4801<I/O EX-
PANDER>. IC801 controls proper fan spinning speed based upon this atmosphere data. (PRESS_SENSOR)
G- Sensor (IC5711)
When the installation angle of the projector exceeds a specified degree, the fan speed will be increased to keep the
best cooling performance. IC5711 is a sensor to detect the angle of the installed projector.
[NO POWER]
When one of the fans is failure, it cannot be turned on the projector due to the power failure protection.
Check the Lamp Warning LED indication
Check that the connectors of the fans and boards are connected firmly.
Chassis Description & Troubleshooting
Fig.6-
1
IC8841
IC5711
IC4895
IC8821
Summary of Contents for PLC-XF60
Page 104: ... 104 IC Block Diagrams TC4052BFT Selector IC9005 TB1274AF RGB Matrix IC3101 ...
Page 105: ... 105 IC Block Diagrams TC90A69F PAL Y C Separator IC2101 TE7780 I O Expander IC4801 IC4802 ...
Page 106: ... 106 IC Block Diagrams MAS1390 G Sensor IC5711 NJW1141 Audio Selector Controller IC9501 ...
Page 157: ...MM7 XF6000 157 Mechanical Parts List L15 R G Optical Filter WV Optical Filter WV S05 S05 ...
Page 158: ...MM7 XF6000 158 Mechanical Parts List 1 2 0 5 L03 Integrator In Integrator In ...
Page 160: ...MM7 XF6000 160 Mechanical Parts List L09 Mirror R Mirror R S05 S05 ...
Page 161: ...MM7 XF6000 161 Mechanical Parts List L13 Optical Filter R Optical Filter R ...
Page 162: ...MM7 XF6000 162 Mechanical Parts List 162 Relay lens Out L08 Relay Lens Out ...
Page 165: ...MM7 XF6000 165 Mechanical Parts List ...
Page 166: ... MM7A Oct 2004 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 170: ...Diagrams Drawings MM7 XF6000 ...