9.11.18 CR_SECURITY Command
Command
“CR_ SECURITY” [CR]
Details
Get ON/OFF setting status of Security on menu.
Response
Acceptable
“000_%1” [CR]
%1
“ON” ---------------- PJ Lock is set to On1/ On2 on the menu
“OFF” --------------- PJ Lock is set to OFF on the menu
Unacceptable “Error Code” [CR]
9.11.19 CR_PJLOCKNOW Command
Command
“CR_PJLOCKNOW” [CR]
Details
Get actual setting status of PIN code lock
Response
Acceptable
“000_%1” [CR]
%1
“LOCK” ------ PJ is locked
PIN code lock is set to ON1/ON2 on the menu and PJ PIN
code is not entered, therefore PJ is actually locked.
“FREE” ------- PJ is unlocked (either A or B)
A) PJ lock is set to OFF on the menu
B) PJ lock is set to ON1/ON2 on the menu, but PIN code
Lock mode is canceled because PJ PIN code is entered.
Unacceptable “Error Code” [CR]
9.11.20 CR_PJLOCKMENU Command
Command
“CR_PJLOCKMENU” [CR]
Details
Get ON/OFF setting status of PIN code lock on menu
Response
Acceptable
“000_%1” [CR]
%1
“ON1” -------------------- PIN code lock ON 1 is set on the menu
“ON2” -------------------- PIN code lock ON 2 is set on the menu
“OFF” -------------------- PIN code lock OFF is set on the menu
Unacceptable “Error Code” [CR]
9.11.21 CR_TESTPAT Command
Command
“CR_TESTPAT” [CR]
Details
Get setting status of Test pattern
Response
Acceptable
“000_%1” [CR]
%1
“COLOR” ---------------------- Color bar is displayed
“GRAD1” ---------------------- 16step(white
→
black) is displayed
“GRAD2” ---------------------- 16step(white
←
black) is displayed
“GRAD3” ---------------------- 16step(white
↓
black) is displayed
“GRAD4” ---------------------- 16step(white
↑
black) is displayed
“WHITE” ---------------------- All white is displayed
“BALCK” ---------------------- All black is displayed
“CROSS” --------------------- Cross is displayed
“OFF” ---------------------------Test pattern diplay is not displayed
Unacceptable “Error Code” [CR]