PLC-ET30L Expand Serial Command Functional Specifications
41/62
9.4.14 CR_IMGGMD Command
Command
“CR_IMGGMD” [CR]
Details
Get setting status of Dynamic/Standard/Real/Cinema in Image Gamma
Response
Acceptable
“000_%1” [CR]
%1
“DYN” ------------ Dynamic
“STD” ------------ Standard
“REL” ------------ Real
“CNM” ------------ Cinema
Unacceptable
“?” [CR]
9.5 PC Adjust Status Read Command
9.5.1 CR_FSYNC Command
Command
“CR_FSYNC” [CR]
Details
Get value of Fine Sync
Response
Acceptable
“000_%1” [CR]
%1
“0000 – 0031”
Unacceptable
“Error Code” [CR] --- When command is not available in the given
condition (such as being selected input)
“?” [CR] --- When unknown command is received
9.5.2 CR_TDOTS Command
Command
“CR_TDOTS” [CR]
Details
Get value of Total Dots
Response
Acceptable
“000_%1” [CR]
%1
“mmmm” – “nnnn”
(mmmm = Display area H + Position H)
(nnnn = Maximum value less than 140 MHz of Dot Clock)
Unacceptable
“Error Code” [CR] ------------------------ When command is not
available in the given condition (such as being selected input
“?” [CR] ------------------- When unknown command is received
9.5.3 CR_CLPPHASE Command
Command
“CR_CLPPHASE” [CR]
Details
Get value of Clamp Phase value
Response
Acceptable
“000_%1” [CR]
%1
“0001”~“nnnn”
(“nnnn” depends on input signal)
Unacceptable
“Error Code” [CR]