PLC-ET30L Expand Serial Command Functional Specifications
17/62
8.4.5 CF_SHARP Command
Command
“CF_SHARP_%1” [CR]
%1
“000-015”--------------- Directly specify setting value of Sharpness
“UP”--------------------- Increment setting value of Sharpness by 1
“DN”--------------------- Decrement setting value of Sharpness by 1
Details
Set user controlled value of Sharpness (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.4.6 CF_GAMMA Command
Command “CF_GAMMA_%1” [CR]
%1
“000-015”---------------- Directly specify setting value of Gamma
“UP”---------------------- Increment setting value of Gamma by 1
“DN”---------------------- Decrenment setting value of Gamma by 1
Details
Set user controlled value of Gamma (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFFstatus, the value returns to the
original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.4.7 CF_WBAL- Command
Command
“CF_WBAL-%1_%2” [CR]
%1
“R” --------- RED
“G” --------- GREEN
“B” --------- BLUE
%2
“000-063”------ Directly specify value of Color selected in %1 of White Balance.
“UP”---------Increment setting value of Color specified in %1 of White Balance by 1.
“DN”-------- Decrement setting value of Color specified in %1 of White Balance by 1.
Details
Set value of Color specified in %1 of White Balance (Available only in the normal
Power ON status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code”[CR]