When the projection lamp of the projector reaches its end
of life, the Lamp replacement icon appears on the screen
and LAMP REPLACE indicator lights yellow. Replace the
lamp with a new one promptly. The timing when the LAMP
REPLACE indicator should light is depending on the lamp
mode.
For continued safety, replace with a lamp of the
same type. Do not drop a lamp or touch a glass
bulb! The glass can shatter and may cause injury.
Allow a projector to cool for at least 45 minutes
before you open the Lamp Cover. The inside of
the projector can become very hot.
CAUTION
Lamp Replacement
CAUTION
Maintenance and Cleaning
Follow these steps to replace the lamp.
Turn off the projector and unplug the AC power cord.
Let the projector cool for at least 45 minutes.
Loosen the two (2) screws that secure the lamp. Lift
the lamp out of the projector by using the handle.
1
3
Replace the lamp with a new one and secure the two
(2) screws. Make sure that the lamp is set properly.
Close the lamp cover and secure the screw.
Loosen the screw and open the lamp cover.
2
Connect the AC power cord to the projector and turn
on the projector.
6
Reset the lamp counter .
See “Resetting the Lamp Counter” on the next page.
5
Screw
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.
l
Model No . of your projector
: PDG-DWL2500
l
Replacement Lamp Type No .
: POA-LMP13
(Service Parts No. 610 351 3744)
Top Panel
When replacing the lamp because it has stopped
illuminating, there is a possibility that the lamp
may be broken. If replacing the lamp of a projector
which has been installed on the ceiling, you should
always assume that the lamp is broken, and you
should stand to the side of the lamp cover, not
underneath it. Remove the lamp cover gently.
Small pieces of glass may fall out when the lamp
cover is opened. If pieces of glass get into your
eyes or mouth, seek medical advice immediately.
CAUTION
Screws
Handle
Lamp replacement icon
WARNING:
TURN OFF THE UV LAMP BEFORE
OPENING THE LAMP COVER
4
Note:
The Lamp replacement icon will not appear when