Page 13
Document No.
Document Name
SANYO Electric Co., Ltd.
Reliability
(1/3)
1. Estimate Conditions
1) Standard test position
For the standard test position, the + side of the Z axis shall be in the upper direction, provided
that the Z axis shall be the outgoing beam and the direction of the outgoing beam shall be +
side.
2) Standard Estimate Environments
Temperature : (22 ± 2)
°
C
Humidity
: (50 ± 5) % RH
However, when no doubt occurs regarding the judgment, the test may be performed under the
following conditions.
Temperature : (15 to 30)
°
C
Humidity
: (45 to 85) % RH
3) Disc to be estimated
Test Disc made by ALMEDIO Inc. ROM DISK, DA DISK, CD-R DISK (RICOH),
CD-RW (RICOH, MITSUBISHI CHEMICAL)
DVD-R/+R(RICOH,MITSUBISHI CHEMICAL)
DVD-RW/+RW(RICOH,MITSUBISHI CHEMICAL)
However, when no doubt occurs regarding the judgment, TCD-784 made by ALMEDIO Inc.
may be used.
4) Power Supply Voltage
Power supply
: DC 5
×
(1 ± 5 %) V
Power supply
: DC 12
×
(1 ± 10 %) V
2. Reliability
The results should conform to the criteria of each item after the test has been performed under
the following conditions.
There shall be no crack, deformation or distortion from the external view of the product after
the test.
Unless otherwise specified, the measurement conditions of this test for each item shall be
subject to the above estimate conditions.
However, the temperature in this test shall be specified to the surrounding temperature of the
drive unit, rather than the surrounding temperature of the set unit where this product is
built-in.
Summary of Contents for CRD-BPDV2
Page 1: ......
Page 2: ......
Page 29: ...Page 28 Document No Document Name SANYO Electric Co Ltd Notes for Handling 4 5 Package ...