PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
111
ABS Sensor Format
ABSF
Remote Operator Mode:
4
Page:
5
Default Value:
$$$$
Function:
Setting Range:
11 Formats
Description:
•
A desired format can be selected from the following.
2048 FMT
4096 FMT
8192 FMT
16384 FMT
32768 FMT
65536 FMT
131072 FMT
262144 FMT
524288 FMT
1048576 FMT
2097152 FMT
•
You must turn “OFF” the control power before making the change.
•
Your change is effective only after Func6, Bit 7 has been set a “1”.
•
If the above operation (Func6, Bit 7 to “1”) is ignored, the parameter change is invalid, thus, does not take
place.