PY Manual
Copyright © 2006 SANYO DENKI
AMERICA
, Inc.
67
The following online options are available.
♦
Set Parameters – Allows access to parameter values for the drive. Current values can
be viewed or modified.
♦
Digital Monitor – The Digital Monitor screen allows you to monitor servo status,
CN1 I/O, torque, and miscellaneous feedback and command values.
♦
Alarm Trace – This screen shows the current error in addition to a history of the last
seven errors.
♦
Test Mode – This screens provides commands for jogging the motor, tuning the
motor, and adjusting the velocity or torque offset.
For offline use, complete the following steps
1)
After the Main Menu is displayed, click the EDIT PARAMETER button.
2)
Browse to the folder on your computer that contains the saved configuration.
3)
Select the file and click on the LOAD button. Parameters for the selected
configuration will be displayed.
Parameters are placed in six tabs labeled Mode 0-4 and Mode8. Current values for a
parameter can be viewed by clicking on the required tab and using the scroll bars to find
the desired parameter. Each row on the Mode tab has a Page assigned in the left column.
This numbering system allows you to easily locate the parameter when it is referenced in
the PY manual. The parameters are located in the same Mode areas as the Remote
Operator.
To modify a parameter, click on the desired parameter to be modified. Its current value
will be displayed in the Input Value window. This value can be changed to a different
value. For parameters where one of a set number of choices is available, use the pull-
down for the Input Value Window to select a different choice. If the Input Value
Window requires a numeric value, type in a new value that is within the Setting Range
displayed for the selected parameter. Once the value is changed, hit the “Set” button to
send the new value to the drive.
After you have made modifications to a configuration (offline or online), the software
will prompt you to save your settings when you attempt to return to the Main Menu.
Provide a file name and browse to a desired path to preserve the settings.
Offline
Modifications
Amplifier
Parameter
Modifications
Saving Amplifier
Parameter Values