
― 52 ―
― 51 ―
Note:
・
> 6 A: Cool down more than 3 minutes after measuring 1 minute.
< 6 A Continuable
Measuring
range
Frequency (Hz)
Input sensitivity (Sine wave)
Frequency range
5.0000 A
1 A
10.00 Hz
~
3.000 kHz
10.000 A
8 A
5-11 Measurements with Optional Products
5-11-1 AC flexible clamp sensor: CL3000
(Max. measurable current 3000 A ac)
1) What to measure
50/60 Hz sine wave current such as consumption current of
home appliances, current of power supply equipments, and etc.
2) Measuring ranges
30 A, 300 A, and 3000 A
3) Measuring procedure
①
Connect the red plug of the current probe to the V measuring
terminal and the black one to the COM terminal.
②
Set the function selector to
, then press the SELECT
button to select [
/Hz ].
1. Do not apply any input exceeding max. rated input for the
separately available accessories.
2. 2. Do not switch the function selector while measuring.
1. To make measurements of consumption current for home
appliances using a current probe, use a line separator as
shown in the drawing below.
CAUTION
WARNING
2. Overall accuracy is calculated using the total of each probe's
accuracy.
/
/ Hz