µ
µ
/
µ
―
3 6
―
―
3 5
―
5-9-2 Current (A) measurement
(
,
Max. rated input current AC 10A dc/ac
)
1) What to measure
・
(DC current): DC circuit current
・
(AC current): AC circuit current
・
/
(DC current component / AC current component)
・
Hz (Frequency): Measuring current frequency
2) Measuring ranges
6.000A and 10.00A
3) Measuring procedure
①
Set the function selector to
, and press the SELECT button to
select a display style from [
], [
/ ], and [
/ Hz].
②
Connect the red plug of the test lead to
measuring terminal
and the black one to the COM terminal.
③
Connect the test pins (red and black) in series with the circuit to
measure.
・
: Connect the black test pin to the lower electric potential side
of the circuit to measure, and the red test pin to the higher
electric potential side in series with the object.
・
: Connect the test pins (red and black) in series with the circuit
to measure.
④
Read the display.
Note:
Measuring
Range
Frequency (Hz)
Input sensitivity(Sine wave)
Frequency range
600.0
µ
A
60
µ
A
15.00Hz
〜
3.000kHz
6000
µ
A
600
µ
A
60.00mA
40mA
600.0mA
60mA