5 0
―
―
4 9
―
[ 8] SPECIFICATIONS
8-1 General Specifications
Operation
method
Delta-sigma modulation
LCD display
Main display
9,999 counts:
DCV, ACV, Logic-Level Frequency(Hz),
and Duty Cycle
6,000 counts:
DCmV, ACmV, Resistance, Continuity,
Capacitance, DCA, DCmA, DC
µ
A,
ACA, ACmA, and AC
µ
A
2,000 counts: Diode
Bar graph: Up to 41 segments
Sub display
9,999 counts: ACV, Frequency (Hz)
6,000 counts: ACmV, ACA, ACmA,
and AC
µ
A
Over-rang e
ind ication
Over-range input turns on "OL" indicator at the numeric part.
Samp ling rate
Numeric part 5 times / sec.
Bar graph part 60 times / sec.
Low battery
indication
Decreasing the internal battery voltage to approx. 7V
turns the battery mark on.
Operating
conditions
Altitude: < 2,000m Pollution degree: II
Operating
temperature/
humidity
5
℃
to 40
℃
: non-condensing
5
℃
to 31
℃
: 80%RH (Max.)
31
℃
to 40
℃
: decreasing 80% to 50% linearly
Storage
temperature/
humidity
-10
℃
to 40
℃
: 80%RH (Max.) non-condensing (with
battery removed)
40
℃
to 50
℃
: 70%RH (Max.) non-condensing
(Remove the battery, if the equipment is not going to
be used for a long time.)
Temperature
coefficient
0.15 x (accuracy @23± 5
℃
)/
℃
@(0
℃
to 18
℃
or
28
℃
to 40
℃
)
Power source
Single manganese 9V battery 6LR61
(IEC6LF22, NEDA1604A)
AC sensing
method
Average sensing RMS calibrated
OVERVOLTAGE CATEGORY
Equipment of CAT I: Secondary cable runs from a power supply
transformer connected to a wall socket.
Equipment of CAT II: Primary cable runs of power-consuming
equipments from a wall socket.
Equipment of CAT III: Primary cable runs of equipments directly
connected to a distribution board and
cable runs from a distribution board to wall
sockets.
Equipment of CAT IV: Cable runs from an incoming line to a
distribution board.
Auto Power
Saving
Approx. 30 minutes after the last operation
Safety
Compliances
IEC61010-1:2001
IEC61010-031:2008
Category II for 1000V ac and dc
Category III for 600V ac and dc
mA
µ
A
Category II for 500V ac and dc
Category III for 300V ac and dc
Category II for 500Vac and 300Vdc
Category III for 300Vac and 150Vdc
EMC
Meets EN61326-1:2006
In an RF field of 3V/m:
Capacitance function is not specified.
Other function ranges:
Total Accuracy = ± (Specified% rdg + 100digits)
Performance above 3V/m is not specified.
Dimensions
without holster Approx. L175mm× W80mm× H40mm
with holster Approx. L184mm× W86mm× H52mm
Weight
without holster Approx. 360g
with holster Approx. 430g
Power
consumption
Approx. 48mW / approx. 0.45mW (Auto Power Saving)
Battery life
Approx. 60hours (DCV measurement)
Accessories
Test leads (TL-23a),
Holster (H-700) with light shieliding magnet cap,
Instruction manual