1.
Overview
This multimeter is characterized by a compact rugged construction with
protective holster and stand. The LCD Screen with 16mm display gives clear
readings even in low light when the back light can be switched on. Features
include sophisticated A/D converter in conjunction with overload protection.
Measures: DC & AC voltage, DC current Resistance and Temperature.
Tests: Continuity, Diode forward bias and Transistor hFE gain. Includes standard
probe test leads as well as temperature probe leads.
Before use you will need to fit a 9V PP3 battery (not supplied) in the compartment
located on the back of the meter. To open the compartment remove the cross
headed screw from the lid and lever open, clip the terminal studs over the battery
terminal caps, close the compartment lid and screw tightly shut.
2. Panel Layout
1 LCD Display: 3½ digits, character 16mm high
2 Data-hold Switch (HOLD).
3 Back Light Button Switch: Press this button to switch on back light in low light
conditions, the light will switch off automatically in 5 seconds. Press again to
switch it on again. If the battery power is low the light will dim.
4 Rotary Switch: use this switch to select functions and ranges
5 T+V
Ω
mA Input socket
;
10A Input socket
;
T- COM Input socket
3. Safety Information
3-1 This meter is designed according to IEC-1010 for electronic measuring
instruments with an over-voltage category (CAT II) and pollution 2
3-2 Follow all safety and operating instructions to ensure that the meter is used
safely and is kept in good operating condition.
3-3 Safety symbols:
important safety information, refer to the operating manual.
Danger - high voltage.
Double insulation (protection Class II)
4. User Precautions
4-1 For safe use of the meter, use only the test leads supplied. If your test leads
are damaged make sure they are replaced with leads of the same quality and
specification.
4-2 Always use the meter with the blue holster in place.
4-3 Always check that the range switch is set to the correct position for the test
being made.
4-4 Do not exceed the maximum inputs shown on the dial or in these instructions.
Exceeding set inputs increases the chance of electric shock and can damage
your meter.
4-5 When measuring TV sets or switched power, avoid high voltage components
and high output pulse supplies.
4-6 During measurement be careful not to alter the Range switch position
accidentally.
4-7 Take extra care to avoid bodily contact with live surfaces when measuring
high voltage (especially more than DC 60V & AC 30V).
4-8 The Protection fuse should only be replaced with a fuse of the same type
and specification.
5. GENERAL SPECIFICATIONS
5-1 Max Voltage between input terminal and Earth Ground: CAT II 600V
5-2 Over-range Indication: display “1” for the significant digit.
5-3 Automatic display of negative polarity “_” .
5-4 Low Battery Indication: ‘ ’ displayed
5-5 Max LCD display: 1999 (31/2 digits)
5-6 Fuse protection: F-200mA/250V (Ø5x20mm)
5-7 Power Supply: 9V battery, 6F22 or NEDA 1604
5-8 Operating Temp.: 0
˚
C to 40
˚
C (relative humidity <85%)
5-9 Storage Temp.:-1
˚
C to 50
˚
C (relative humidity <85%)
5-10 Guaranteed precision Temp.: 23
±
5
˚
C (relative humidity <85%)
5-11 Dimensions: 69x138x31mm (with holster)
5-12 Weight: approx. 170g (including battery)
6. Testing Specifications
Accuracy is specified for a period of 1 year after calibration and a temperature
from 18
˚
C to 28
˚
C (64
˚
F to 82
˚
F) with relative humidity up to 75%.
6-1 DC Voltage
Range
Resolution
Accuracy
200mV
0.1mV
±
(0.5% of rdg + 10 digit )
2V
1mV
±
(0.5% of rdg + 10 digits)
20V
10mV
±
(0.5% of rdg + 10 digits)
200V
100mV
±
(0.8% of rdg + 10 digits)
600V
1V
±
(1.2% of rdg + 10 digits)
- Input Impedance: 10M
Ω
- Overload protection: 250V for 200mV range, effective DC or AC 600V for other
ranges
6-2 AC Voltage
Range
Resolution
accuracy
200V
100mV
±
(1.2% of rdg + 20 digits)
600V
1V
±
(1.2% of rdg + 20 digits)
- Frequency Range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave
6-3 DC Current
Range
Resolution
Accuracy
2mA
1µA
±(1.0% of rdg + 10 digits)
20mA
10µA
±(1.0% of rdg + 10 digits)
200mA
100µA
±(1.5% of rdg + 20 digits)
10A
10mA
±
(3.0% of rdg + 20 digits)
- Overload protection: F 200mA/250V fuse
Note: [1] 10A range: not fused
6- 4 Resistance
Range
Resolution
Accuracy
200Ω
0.1Ω
±(1.5% of rdg + 25 digits)
2KΩ
1Ω
±(0.8% of rdg + 20 digits)
20KΩ
10Ω
±(0.8% of rdg + 20 digits)
200KΩ
100
±(0.8% of rdg + 20 digits)
2MΩ
1KΩ
±(1.2% of rdg + 25 digits)
- Overload protection: 250V effective value
6-5 Temperature
Range
Test Range
Accuracy
-20~400 ˚C
1˚C
±(1.2% of rdg +5 digits)
400~1000 ˚C
1˚C
±(2.0% of rdg + 15 digits)
- Overload Protection: 250V DC or rms AC
6-6 Transistor hFE Test
Range
Test Range
Test Current / Voltage
NPN & PNP
0-1000
Ib=10uA / Vce=3V
6-7 Diode Test
Range
Resolution
Function
1mV
Display: read approximate forward
voltage of diode
- Overload Protection: 250V effective value
- Forward DC current: approximate 1mA
n
Reversed DC voltage: approximate 3.0V
USER GUIDE
Philex Customer Careline 08457 573479
Digital Multimeter with
Temperature Measurement
83002R
Battery
Compartment
Insert 9V PP3