background image

1. 

Overview

 

This  multimeter  is  characterized  by  a  compact  rugged  construction  with 
protective holster and stand. The LCD Screen with 16mm display gives clear 
readings  even  in  low  light  when  the  back  light  can  be  switched  on.  Features 
include sophisticated A/D converter in conjunction with overload protection.
Measures:  DC  &  AC  voltage,  DC  current  Resistance  and  Temperature.  
Tests: Continuity, Diode forward bias and Transistor hFE gain. Includes standard 
probe test leads as well as temperature probe leads.
Before use you will need to fit a 9V PP3 battery (not supplied) in the compartment 
located on the back of the meter. To open the compartment remove the cross 
headed screw from the lid and lever open, clip the terminal studs over the battery 
terminal caps, close the compartment lid and screw tightly shut.

2. Panel Layout

 

1  LCD Display: 3½ digits, character 16mm high
2  Data-hold Switch (HOLD).
3  Back Light Button Switch: Press this button to switch on back light in low light  
 

conditions, the light will switch off automatically in 5 seconds. Press again to  

 

switch it on again. If the battery power is low the light will dim.

4  Rotary Switch: use this switch to select functions and ranges
5  T+V 

Ω 

mA Input socket

10A Input socket

T- COM Input socket

3.  Safety Information

3-1  This  meter  is  designed  according  to  IEC-1010  for  electronic  measuring  
 

instruments with an over-voltage category (CAT II) and pollution 2

3-2  Follow all safety and operating instructions to ensure that the meter is used  
 

safely and is kept in good operating condition.

3-3  Safety symbols:

 important safety information, refer to the operating manual.
 Danger - high voltage.

 

Double insulation (protection Class II)

4.  User Precautions 

4-1  For safe use of the meter, use only the test leads supplied. If your test leads  
 

are damaged make sure they are replaced with leads of the same quality and  

 

specification.

4-2  Always use the meter with the blue holster in place.
4-3  Always check that the range switch is set to the correct position for the test  
 

being made.

4-4  Do not exceed the maximum inputs shown on the dial or in these instructions.  
 

Exceeding set inputs increases the chance of electric shock and can damage  

 

your meter.

4-5  When measuring TV sets or switched power, avoid high voltage components  
 

and high output pulse supplies.

4-6  During  measurement  be  careful  not  to  alter  the  Range  switch  position  
 

accidentally.

4-7  Take extra care to avoid bodily contact with live surfaces when measuring  
 

high voltage (especially more than DC 60V & AC 30V).

4-8  The Protection fuse should only be replaced with a fuse of the same type  
 

and specification.

5. GENERAL SPECIFICATIONS 

5-1  Max Voltage between input terminal and Earth Ground: CAT II 600V 
5-2  Over-range Indication: display “1” for the significant digit.
5-3  Automatic display of negative polarity “_” .
5-4  Low Battery Indication: ‘ ’ displayed
5-5  Max LCD display: 1999 (31/2 digits)
5-6  Fuse protection: F-200mA/250V (Ø5x20mm)
5-7  Power Supply: 9V battery, 6F22 or NEDA 1604
5-8  Operating Temp.: 0

˚

C to 40

˚

C (relative humidity <85%)

5-9  Storage Temp.:-1

˚

C to 50

˚

C (relative humidity <85%)

5-10 Guaranteed precision Temp.: 23

±

˚

C (relative humidity <85%)

5-11 Dimensions: 69x138x31mm (with holster)
5-12 Weight: approx. 170g (including battery)

6. Testing Specifications 

Accuracy is specified for a period of 1 year after calibration and a temperature 
from 18

˚

C to 28

˚

C (64

˚

F to 82

˚

F) with relative humidity up to 75%.

6-1 DC Voltage

Range

Resolution

Accuracy

200mV

0.1mV

±

(0.5% of rdg + 10 digit )

2V

1mV

±

(0.5% of rdg + 10 digits)

20V

10mV

±

(0.5% of rdg + 10 digits)

200V

100mV

±

(0.8% of rdg + 10 digits)

600V

1V

±

(1.2% of rdg + 10 digits)

- Input Impedance: 10M

Ω

- Overload protection: 250V for 200mV range, effective DC or AC 600V for other 

ranges

6-2 AC Voltage

Range

Resolution

accuracy

200V

100mV

±

(1.2% of rdg + 20 digits)

600V

1V

±

(1.2% of rdg + 20 digits)

- Frequency Range: 40 to 400Hz
- Response: average, calibrated in rms of sine wave

6-3 DC Current

Range

Resolution

Accuracy

2mA

1µA

±(1.0% of rdg + 10 digits)

20mA

10µA

±(1.0% of rdg + 10 digits)

200mA

100µA

±(1.5% of rdg + 20 digits)

10A

10mA

±

(3.0% of rdg + 20 digits)

- Overload protection: F 200mA/250V fuse
Note: [1] 10A range: not fused

6- 4 Resistance

Range

Resolution

Accuracy

200Ω

0.1Ω

±(1.5% of rdg + 25 digits)

2KΩ

±(0.8% of rdg + 20 digits)

20KΩ

10Ω

±(0.8% of rdg + 20 digits)

200KΩ

100

±(0.8% of rdg + 20 digits)

2MΩ

1KΩ

±(1.2% of rdg + 25 digits)

- Overload protection: 250V effective value

6-5 Temperature 

Range

Test Range

Accuracy

-20~400 ˚C

1˚C

±(1.2% of rdg +5 digits)

400~1000 ˚C

1˚C

±(2.0% of rdg + 15 digits)

- Overload Protection: 250V DC or rms AC

6-6 Transistor hFE Test 

Range

Test Range

Test Current / Voltage

NPN & PNP

0-1000

Ib=10uA / Vce=3V

6-7 Diode Test

Range

Resolution

Function

1mV

Display: read approximate forward 

voltage of diode

- Overload Protection: 250V effective value
- Forward DC current: approximate 1mA

Reversed DC voltage: approximate 3.0V

USER GUIDE

Philex Customer Careline 08457 573479

Digital Multimeter with

Temperature Measurement

83002R

Battery 

Compartment

Insert 9V PP3