background image

SANUVOX - MODEL GC S300-G2

 - 7  

3. GENERAL OPERATING INFORMATION

DOOR SWITCH

MODE SELECTOR

OPERATIONS

SMART SYSTEM 

LED STATUS DISPLAY

FUNCTION 

The HEPA/UV air purifier is comprised of a fan, 
speed selection switch, 2 stages of filtration 
and the cabinet enclosure system. The fan 
pulls air through the prefilter and pushes 
the same air through the HEPA filter which 
removes 99.97% of particles that are 0.3μm 
or larger in size. 

The GC S300-G2 HEPA/UV Purifier is designed 
to kill bacteria, viruses, odor causing mold and 
fungus as well as chemical odors and VOC's 
that pass through the unit. The ultra-violet band 
light inhibits and kills mold, fungus, bacteria, 
viruses and microbial growth on 100% of 
the air flowing through the unit. The actual 
percentage of destruction depends on the 
velocity of the air, and the pollutant(s) treated.

LED DISPLAY 

The UV Lamp will function when the blower is 
in operation. There are two LED indicators on 
the front panel. The Amber LED indicates that 
the UV Lamp is on; the Red LED indicates that 

the Ballast is functioning. If the Ballast (Red) 
LED is on, and the Lamp (Amber) LED is off, 
the UV lamp is not functioning. If both LED 
lights are off, the ballast is not functioning.

RECOMMENDED OPERATION 

The return plenum mount model operates in 
conjunction with your forced air HVAC system. 
A forced air distribution system continuously 
circulates the air inside your home. The HEPA/
UV air purifier operates on the principal of 
bypass filtration, which means that a portion of 
the air being returned to the furnace is filtered 
on each pass. Over time all the air in the home 
will pass through the unit. It is recommended 
that the furnace blower be in operation 
whenever the system is in operation. 

For stand-alone attic installation, the HEPA/
UV air purifier must be operated continuously 
whenever a part of the system is located in an 
unconditioned space to avoid condensation in 
the ductwork when the temperature is below 
freezing (32°F ,0°C). 

Maintenance of the unit should be performed 
at regular intervals to keep the benefits of the 
HEPA/UV air purifier.

OPERATION MODE OPTIONS 

The unit features two speeds of operation. The 
speed selection switch is located on the front of 
the motor assembly. At lowest speed the unit will 
provide 200 CFM of clean air while at highest 
speed, the unit will provide 300 CFM of clean air. 
It is recommended that the unit be operated on 
the highest speed at all times to maximize the 
benefits of the HEPA/UV air purifier. 

An access door is provided at the front of the 
unit to permit access to the filters and speed 
selection switch. Opening the latch on the right 
side of the unit will permit the door to swing 
open. A safety door interlock switch cuts the 
power to the motor. If necessary, the door can 
be removed from the cabinet hinges by holding 

the top part of the door with one hand and gently 
tapping on the bottom edge of the door with the 
other hand to release the door from its hinges.

OWNER’S OPERATION GUIDE

• II

• I

Maximum Filtration

Normal Filtration

Summary of Contents for GC S300-G2

Page 1: ...INSTALLATION MAINTENANCE OPERATION GUIDE MODEL GC S300 G2 STAND ALONE UVC HEPA AIR PURIFIER ITEM 101275 ...

Page 2: ...t _________________________________ Never expose eyes or skin to ultra violet light from any source The GC S300 G2 must be unplugged before performing maintenance or service Personal injury may result _________________________________ Do not touch lamp glass without gloves Reduced performance of lamp may result Clean lamp after handling _________________________________ Lamp contains a small quant...

Page 3: ...defective part is returned to our distributor The replacement part assumes the unused portion of the warranty BOX CONTENT INCLUDES GC S300 G2 HEPA UV AIR PURIFIER Power cord 5 FT Plenum seal 7 5 FT Screws 16 8 x 32 x 1 2 Template 2 Ultraviolet UVC Lamps J Type 10 5 266 7 mm Pre Filter HEPA Filter 2 collars Uninsulated flex ducting TABLE OF CONTENTS 1 GETTING STARTED 1 1 Unpacking and inspection 3 ...

Page 4: ... mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 1...

Page 5: ...LL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filter and it is located on the units motor plate STEP 1 Mount Hepa STEP 2 Finishing Figure 2 1a Install unit using all supplied fastening hardware Figure 2 2a Remove protective plastic covers from all filters and install in proper location Figure 2 2b Replace door and insert power cord into the recepta...

Page 6: ...dle lamp from the ceramic ends STEP 2 Remove the screws holding the front plate of the GC S300 G2 to access the clamp assembly STEP 4 Replace the front plate with the screws removed in 2 above STEP 5 Repeat the same process for the second lamp STEP 3 Position lamp inside the aluminum enclosure Route 4 pronged end of lamp through clamp Clamp is tightened by moving lever perpendicular to the clamp C...

Page 7: ...r purifier operates on the principal of bypass filtration which means that a portion of the air being returned to the furnace is filtered on each pass Over time all the air in the home will pass through the unit It is recommended that the furnace blower be in operation whenever the system is in operation For stand alone attic installation the HEPA UV air purifier must be operated continuously when...

Page 8: ...lly friendly IMPORTANT ALWAYS UNPLUG UNIT BEFORE SERVICING 4 1 CHANGING FILTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 3 TROUBLESHOOTING PROBLEM SUGGESTIONS Unit does not operate Is power cord fully inserted in the unit s connector Is outlet powered Is door interlock switch operating Unit operates only on one speed Possible loos...

Page 9: ...parts of replacement parts SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTR...

Page 10: ...Sanuvox Technologies Inc 146 Barr Street St Laurent QC H4T 1Y4 Canada T 1 888 SANUVOX F 1 514 382 6475 www sanuvox com info sanuvox com ...

Reviews: