3-YEAR WARRANTY

 — Except for the UV Lamp and Ballast, this 

Sanuvox Technologies Inc. product is warrantied to be free from defects 
in material and workmanship under normal use and maintenance for 
a period of three years from the date of original installation. A new 
or remanufactured part to replace the defective part will be provided 
without charge for the part itself, through a qualified servicing Sanuvox 
Technologies Inc. dealer or distributor, PROVIDED the defective part is 
returned to our distributor. The replacement part assumes the unused 
portion of the warranty. 

COMMERCIAL LAMP WARRANTY

 — The Sanuvox Technologies Inc. 

Ultra-Violet Lamps are warrantied to be free from defects and operate 
for 2 years after installation, under normal use and maintenance in a 
commercial application. A new lamp to replace the defective lamp will be 
provided without charge for the part itself, through a qualified servicing 
Sanuvox Technologies Inc. dealer or distributor, PROVIDED the defective 
part is returned to our distributor. The replacement part assumes the 
unused portion of the warranty. 

3-YEAR BALLAST WARRANTY

 — The Sanuvox Technologies Inc. 

Electronic Ballast is warrantied to be free from defects and operate for 
three (3) years after installation, under normal use and maintenance 
in a residential or commercial application. A new ballast to replace 
the defective ballast will be provided without charge for the part itself, 
through a qualified servicing Sanuvox Technologies Inc. dealer or 
distributor, PROVIDED the defective part is returned to our distributor. 
The replacement part assumes the unused portion of the warranty. 

THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR 

ALLOWANCE OR OTHER COSTS

 incurred for diagnosis, repairing, 

removing, installing, shipping, servicing, or handling of either defective 
parts of replacement parts. SUCH COSTS MAY BE COVERED BY a 
separate warranty provided by the installer. 

LIMITATIONS OF WARRANTIES

 — ALL IMPLIED WARRANTIES 

(INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY) ARE 
HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE 
LIMITED WARRANTY IS GIVEN. THE EXPRESSED WARRANTIES MADE 
IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, 
ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER 
PERSON WHATSOEVER. 

SANUVOX WILL NOT BE RESPONSIBLE FOR:

 

1. Normal maintenance as outlined in the installation and servicing 

instruction or owner's manual. 

2. Damage or repairs required as a consequence or faulty installation or 

application by others. 

3. Failure to start due to voltage condition, blown fuses, open circuit 

breakers or other damages due to the inadequacy or interruption or 
electrical service. 

4. Damage or repairs needed as a consequence of any misapplication, 

abuse, improper servicing, unauthorized alteration, or improper 
operations. 

5. Damage as a result of floods, winds, fires, lightning, accidents, 

corrosive atmosphere, or other conditions beyond the control of 
Sanuvox Technologies Inc. 

6. Parts not supplied or designated by Sanuvox Technologies Inc. 

7. Sanuvox Technologies Inc. products installed outside the continental 

USA, Alaska, Hawaii, and Canada. 

8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR 

COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states 
do not allow the exclusion of incidental or consequential damages, so 
the above limitation may not apply to you. 

Model number:  _________________________________________

Date of installation:  ______________________________________

Name of owner:  ________________________________________

Unit serial number:  ______________________________________

Installed by:  ___________________________________________

Address of installation: ____________________________________

 

 

Sanuvox Technologies Inc.  

146, rue Barr, St-Laurent, QC H4T 1Y4 Canada  

T. 1-888-SANUVOX         F. 1-888-582-6475  

www.sanuvox.com          [email protected]

GC S300-G2  

LIMITED PARTS AND LAMP WARRANTY

Summary of Contents for GC S300-G2

Page 1: ...INSTALLATION MAINTENANCE OPERATION GUIDE MODEL GC S300 G2 STAND ALONE UVC HEPA AIR PURIFIER ITEM 101275 ...

Page 2: ...t _________________________________ Never expose eyes or skin to ultra violet light from any source The GC S300 G2 must be unplugged before performing maintenance or service Personal injury may result _________________________________ Do not touch lamp glass without gloves Reduced performance of lamp may result Clean lamp after handling _________________________________ Lamp contains a small quant...

Page 3: ...defective part is returned to our distributor The replacement part assumes the unused portion of the warranty BOX CONTENT INCLUDES GC S300 G2 HEPA UV AIR PURIFIER Power cord 5 FT Plenum seal 7 5 FT Screws 16 8 x 32 x 1 2 Template 2 Ultraviolet UVC Lamps J Type 10 5 266 7 mm Pre Filter HEPA Filter 2 collars Uninsulated flex ducting TABLE OF CONTENTS 1 GETTING STARTED 1 1 Unpacking and inspection 3 ...

Page 4: ... mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 1...

Page 5: ...LL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filter and it is located on the units motor plate STEP 1 Mount Hepa STEP 2 Finishing Figure 2 1a Install unit using all supplied fastening hardware Figure 2 2a Remove protective plastic covers from all filters and install in proper location Figure 2 2b Replace door and insert power cord into the recepta...

Page 6: ...dle lamp from the ceramic ends STEP 2 Remove the screws holding the front plate of the GC S300 G2 to access the clamp assembly STEP 4 Replace the front plate with the screws removed in 2 above STEP 5 Repeat the same process for the second lamp STEP 3 Position lamp inside the aluminum enclosure Route 4 pronged end of lamp through clamp Clamp is tightened by moving lever perpendicular to the clamp C...

Page 7: ...r purifier operates on the principal of bypass filtration which means that a portion of the air being returned to the furnace is filtered on each pass Over time all the air in the home will pass through the unit It is recommended that the furnace blower be in operation whenever the system is in operation For stand alone attic installation the HEPA UV air purifier must be operated continuously when...

Page 8: ...lly friendly IMPORTANT ALWAYS UNPLUG UNIT BEFORE SERVICING 4 1 CHANGING FILTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 3 TROUBLESHOOTING PROBLEM SUGGESTIONS Unit does not operate Is power cord fully inserted in the unit s connector Is outlet powered Is door interlock switch operating Unit operates only on one speed Possible loos...

Page 9: ...parts of replacement parts SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTR...

Page 10: ...Sanuvox Technologies Inc 146 Barr Street St Laurent QC H4T 1Y4 Canada T 1 888 SANUVOX F 1 514 382 6475 www sanuvox com info sanuvox com ...

Reviews: