4. GENERAL MAINTENANCE INFORMATION

WHEN SHOULD I SERVICE MY UNIT?  

SERVICE AND ACCESSORIES

  

Detailed maintenance information is located 
on the front decal of motor plate. 

PRE-FILTER

 

Replace filter every 3 to 6 months or as needed.

HEPA FILTER

 

Replace filter every 2 to 5 years or as needed. 
Check regularly to maintain maximum 
performance from your HVAC system.  
For replacement filters, contact your local 
HVAC contractor. 

UV LAMP

  

Replace lamps every 2 years. Lamps are 
available through your local HVAC contractor. 

INSIDE THE UNIT

  

Once a year or as needed, clean the interior of 
the unit (Wall and Motor Plate) with a mild and 
non-abrasive soap. It is recommended to use 
products that are environmentally friendly.

IMPORTANT

: ALWAYS UNPLUG UNIT  

BEFORE SERVICING

4.1 CHANGING FILTERS 

After opening the unit’s door, grasp both 
edges of filter and pull with equal force to 
slide out the filter.

4.3 TROUBLESHOOTING 
PROBLEM SUGGESTIONS 

Unit does not operate. 

• Is power cord fully inserted in the unit’s connector? 

 

• Is outlet powered? 

 

• Is door interlock switch operating?

Unit operates only on one speed. 

• Possible loose wire inside electrical box,  

 

   contact your local contractor.

Unit vibrates. 

• Check for excessive dust buildup or missing balancing weight  

 

   on the impeller wheel.

4.4 ELECTRICAL WIRING DIAGRAM

4.2 CLEANING 

Once a year or as needed, clean the interior 
of the unit (Wall and motor plates) using 
mild non-abrasive soap and water. It is 
recommended to use products that are 
environmentally friendly.

INSTALLATION GUIDE

M

Door 

Interlock

Brown 

N

Blue 

Black 

2.5uf 

7.5uf 

G

Speed 

Selection 

UV Power

Supply cord for 

optional UV module

Summary of Contents for GC S300-G2

Page 1: ...INSTALLATION MAINTENANCE OPERATION GUIDE MODEL GC S300 G2 STAND ALONE UVC HEPA AIR PURIFIER ITEM 101275 ...

Page 2: ...t _________________________________ Never expose eyes or skin to ultra violet light from any source The GC S300 G2 must be unplugged before performing maintenance or service Personal injury may result _________________________________ Do not touch lamp glass without gloves Reduced performance of lamp may result Clean lamp after handling _________________________________ Lamp contains a small quant...

Page 3: ...defective part is returned to our distributor The replacement part assumes the unused portion of the warranty BOX CONTENT INCLUDES GC S300 G2 HEPA UV AIR PURIFIER Power cord 5 FT Plenum seal 7 5 FT Screws 16 8 x 32 x 1 2 Template 2 Ultraviolet UVC Lamps J Type 10 5 266 7 mm Pre Filter HEPA Filter 2 collars Uninsulated flex ducting TABLE OF CONTENTS 1 GETTING STARTED 1 1 Unpacking and inspection 3 ...

Page 4: ... mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 12 305 mm 31 795 mm Stage 1 Stage 2 Power Connection 12 305 mm Stage 1 Stage 2 17 432 mm 30 770 mm 4 97 mm 13 327 mm 31 795 mm 17 432 mm 8 203 mm 30 770 mm 4 97 mm 13 327 mm 1...

Page 5: ...LL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filter and it is located on the units motor plate STEP 1 Mount Hepa STEP 2 Finishing Figure 2 1a Install unit using all supplied fastening hardware Figure 2 2a Remove protective plastic covers from all filters and install in proper location Figure 2 2b Replace door and insert power cord into the recepta...

Page 6: ...dle lamp from the ceramic ends STEP 2 Remove the screws holding the front plate of the GC S300 G2 to access the clamp assembly STEP 4 Replace the front plate with the screws removed in 2 above STEP 5 Repeat the same process for the second lamp STEP 3 Position lamp inside the aluminum enclosure Route 4 pronged end of lamp through clamp Clamp is tightened by moving lever perpendicular to the clamp C...

Page 7: ...r purifier operates on the principal of bypass filtration which means that a portion of the air being returned to the furnace is filtered on each pass Over time all the air in the home will pass through the unit It is recommended that the furnace blower be in operation whenever the system is in operation For stand alone attic installation the HEPA UV air purifier must be operated continuously when...

Page 8: ...lly friendly IMPORTANT ALWAYS UNPLUG UNIT BEFORE SERVICING 4 1 CHANGING FILTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 3 TROUBLESHOOTING PROBLEM SUGGESTIONS Unit does not operate Is power cord fully inserted in the unit s connector Is outlet powered Is door interlock switch operating Unit operates only on one speed Possible loos...

Page 9: ...parts of replacement parts SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTR...

Page 10: ...Sanuvox Technologies Inc 146 Barr Street St Laurent QC H4T 1Y4 Canada T 1 888 SANUVOX F 1 514 382 6475 www sanuvox com info sanuvox com ...

Reviews: