User manual
SNC-311RINA, SNC-311RDIA, SNC-311RBIA
SNC-311FEIF, SNC-311FBIF
_________________________________________________________________________________
- 55 -
Anti-Dither:
The camera can only process one event/alarm at the same time. Here you can define the
interval (0-100 seconds) between two events/alarms.
Area:
You can define up to 4 areas for motion detection. By default, the whole area is activated. If
you wish to select only a few areas in the grid, empty the grid by clicking „Remove all“ or
right-click. Drag the mouse into the desired fields in the grid. Proceed in the same way for the
other area definition.
For each area, the sensitivity and threshold for motion detection can be defined.
Record:
Enable the alarm recording function. If enabled, the system makes event-triggered
recordings. If y continuous recording is active, it will not be deactivated. In the recording
there will be a hint regarding the time of this event.
Record delay:
Define the interval between 2 recordings. This interval may range from 10 to 300 seconds.
Default is 10 seconds.
Relay out
(not available for camera models SNC-311FBIF and SNC-311FEIF)
:
By enabling this checkbox, an alarm is activated. The alarm output port has to be set
accordingly.
Alarm delay
(not available for camera models SNC-311FBIF and SNC-311FEIF):
You can delay the alarm output for the specified time after an alarm ended. Delay time
range: 10 to 30 seconds.