background image

Table of Contents

1. Intended Application(s) ................................................... 2
2. Registration ................................................................... 2
3. Specifications     ............................................................ 3
4 . Installation .................................................................... 3

4.1 Remove Compressor Shipping Support...................... 3
4.2 Location .................................................................... 3

4.2A No Ducting ............................................................ 3
4.2B Duct Outlets .......................................................... 3
4.2C Remote Area w/Outlets Ducted ............................. 3

4.3 Electrical Requirements ............................................. 4 
4.4 Install Leveling Feet ................................................... 4
4.5 Condensate Water Removal ....................................... 4

5. Ducting .......................................................................... 4

5.1 Outlet Duct Kit ........................................................... 4

6. Operation ....................................................................... 4

6.1 Humidity Control Adjustment ..................................... 4
6.2 Fan Switch ................................................................ 4

Installation
7. Maintenance .................................................................. 5

7.1 Air Filter..................................................................... 5

8. Service .......................................................................... 5

8.1 Technical description ................................................. 5
8.2 Troubleshooting ......................................................... 5
8.3 Defrost Thermostat .................................................... 6

9. Service Parts List ........................................................... 6
10. Accessory/Replacement Parts List ............................... 6
11. Wiring Diagram ............................................................ 6
Warranty ............................................................................ 7

Precautions

•  Do not operate the Santa Fe

 Advance2 with a cut or 

frayed power cord.

•  Do not unplug the unit by pulling on the cord. Grasp the 

plug firmly and pull it out of the wall socket or power 
receptacle.

• Always use a grounded outlet.
•  Never operate electrical equipment near or in standing 

water.

•  Do not stick your fingers or other objects through the safety 

grill.

•  When changing filters, do not stick fingers or other objects 

in the unit.

•  No user serviceable components. Contact installer or call 

1-800-533-7533, Ext. 8459 for all repair or warranty needs.

•  Do not restrict airflow in to or out of the unit. This may 

cause the unit to overheat.

•  The unit should never be serviced or cleaned while it is 

plugged in.

• Do not sit or stand on the unit, or use as a shelf or table.
•  Before leaving the unit unattended, ensure children do not 

have access to the equipment. Do not allow children to play 
with or near the unit or in its air flow.

•  The unit is designed to be installed indoors only.

Read the installation, operation and maintenance 
instructions carefully before installing and using 
this unit. Proper adherence to these instructions is 
essential to obtain maximum benefit from your Santa Fe 
Advance2 dehumidifier.

Read and Save These Instructions

 WARNING!

 

— This symbol means important 

instructions. Failure to heed them can result in serious 
injury or death.

 CAUTION!

 

— This symbol means important 

instructions. Failure to heed them can result in injury or 
material property damage.

1. Intended Application(s)

The Santa Fe Advance2 is intended for use in crawlspaces  
or basements: however, the unit can be placed in almost  
any residential setting where dehumidification is desired.  
Use in non-residential applications and pool areas may  
void warranty.

The Santa Fe Advance2 works most effectively between 56°  
and 95°.

In order to efficiently control humidity levels, the area in 
which the dehumidifier is to be operated must be free of 
water intrusion or excessive fresh (outside) air infiltration. 
Before installing the Santa Fe Advance2, water intrusion and 
air infiltration problems should be addressed.

2. Registrations

The Santa Fe Advance2 conforms to UL STD 1995.

TABLE OF CONTENTS

2

Santa Fe Advance2 Installer’s & Owner’s Manual

Summary of Contents for Advance2

Page 1: ...anta Fe Products com Designed for Basement and Crawlspace Dehumidification n High capacity n High efficiency n Environmentally friendly n Patent pending dual air distribution INSTALLER S OWNER S MANUAL P N 4034180 Serial No ________________________ Install Date ___________ Sold by Patent Pending Dual Air Distribution ...

Page 2: ...ned while it is plugged in Do not sit or stand on the unit or use as a shelf or table Before leaving the unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be installed indoors only Read the installation operation and maintenance instructions carefully before installing and using this un...

Page 3: ...n 3 Mount 4 above drain 4 Do not install the Santa Fe Advance2 with the exhaust of the unit within 1 of a wall or obstruction Do not place the unit near open water 4 2A No Ducting Figure 1 The simplest installation is to place the Santa Fe Advance2 with no ducting To ensure optimal performance the air inlet and the outlet of the unit must be at least 1 from walls and other obstructions to air flow...

Page 4: ...apter provided or by using a male 3 4 NPT PVC pipe Using either option care must be taken installing adaptor to the drain port Use standard condensate drain routing practices outlined when routing the drain line Be sure the hose is not kinked or otherwise restricted so that water can pass through it Improper hose installation may result in water leakage To increase the efficiency of the unit posit...

Page 5: ...move heat and moisture from incoming air and add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the refrigerant press...

Page 6: ...ifying capacity 1 Dirty air filter or air flow restricted 2 Defrost thermostat loose or defective 3 Low refrigerant charge If none of the above has fixed the issue call technical support at 1 800 533 7533 Ext 8459 9 Service Parts List Call your dealer or 1 800 533 7533 Part No Description 4034011 02 Evaporator 4034093 Capillary Tubes 4028089 Compressor 1970010 Compressor Relay 4029510 Filter drier...

Page 7: ...a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the applicable warranty period The...