Installation Guide
52
Syntax
CLI>BU [Warning Critical] [MUTE] [Enter]
Example:
CLI>BU
Buzzer Attribute:
Warning Beep: Sound 2
Critical Beep: Sound 3
CLI>BU 0x1 0x3
CLI>BUBuzzer Attribute:
Warning Beep: Sound 1
Critical Beep: Sound 3
CLI>
When expander alarm with buzzer, you can temporarily mute it
with the following command. The buzzer still can be activated by
the next different event.
CLI>BU MUTE
When expander alarm with buzzer, you can disable it completely
by command “bu 0 0”. If you would like to enable beeper, the
command for default settings will be “bu 2 3”.
FAN Command
The fan command allows you to set the operate fan speed. Typical parameters
include: LowestSpeed and WarningSpeed are fan speed in speed code from
level 1 to 7. The LowestSpeed is the speed code that fan operate in normal
state, and the WarningSpeed is the speed code that fan operate in warning
state; like as detect a device in over-temperature.
Syntax
CLI> fan LowestSpeed WarningSpeed
Summary of Contents for AccuSTOR AS424X12