69
Adjustment method
Feedback
control
method
Conversion
board
pattern
Maximum load
capacity
versus
Rated value
Adjustment
method
Constant
voltage
control
B, G, H, I
Maximum load
voltage
=
Rated voltage of
the external PT
(1)
Maximum load
voltage
<
Rated voltage of
the external PT
(2)
Constant
current
control
C, G, I
Maximum load
current
=
Rated current of
the main circuit CT
(1)
Maximum load
current
<
Rated current of
the main circuit CT
(2)
D, H
Maximum load
current
=
Rated current of
the unit
(1)
Maximum load
current
<
Rated current of
the unit
(2)
Constant
power
control
E, G, I
Maximum load
voltage
Maximum load
current
=
and
=
Rated voltage of
the external PT
Rated current of
the main circuit CT
(1)
Maximum load
voltage
Maximum load
current
<
or
<
Rated voltage of
the external PT
Rated current of
the main circuit CT
(2)
F, H
Maximum load
voltage
Maximum load
current
=
and
=
Rated voltage of
the external PT
Rated current of
the unit
(1)
Maximum load
voltage
or
Maximum load
current
<
or
<
Rated voltage of
the external PT
Rated current of
the unit
(2)
※
For adjustment of constant power control or patterns G and H, if the voltage and
current both have a maximum load capacity that is smaller than the rated value, use
the maximum load capacity with the larger difference from the rated value.