Sanosil Q-Jet Advanced
4
2.1
Intended Usage
The device is a nebulizer to be used for indoor applications only.
The device is a nebulizer to be used for indoor
applications with Sanosil disinfectants only maximal hydrogen Peroxide content of 7.5%.
Its purpose is to transform the used disinfection liquid into smallest particles and to nebulize them into a room,
thus leading to the consistent disinfection of all uncovered surfaces (3D-disinfection) inside the room.
This device is intended for usage in hospitals, clinics, public transports, etc. as well as in residential-, commercial-
and in- dustrial areas. It is an additional measure following regular cleaning and disinfecting room surfaces. Pre-
cleaning protocol is defined by the respective healthcare facility. Ensure surfaces are dry before nebulizing in order
to maximize the impact.
WARNING
Risk of Damage!
This device nebulizes chemical substances!
The area to be disinfected may only contain items necessary for its use.
Objects made of delicate organic materials, in particular antiques, paintings and precious artifacts
are to be removed!
2.2
Inappropriate Usage
Do always and only use suitable Sanosil disinfectants with a maximal hydrogen Peroxide content of 7.5%. The
usage of any other disinfectant or accessories which are not specifically approved by Sanosil Ltd. is against the
rules herein and can lead to heavy injuries as well as to damaging the device. The device is not meant for use
as a stand-alone disinfection process but rather as an addition to regular cleaning and disinfection.
DANGER
Risk of Injuries!
Danger of explosion
!
Do not use any flammable liquids
!
Do always and only use Sanosil disinfection liquids.
2.3
Danger and Caution Warnings
•
The device must be used in full compliance with this Operation and Maintenance Manual.
•
It is strictly forbidden to use the device in an atmosphere with danger of explosion or flammability, in dusty
areas and in areas with the presence of people or animals. It is an imperative to prevent people from entering
intentionally or inadvertently the room during the nebulization process and during the waiting time
thereafter.
•
The device can only be operated using the original power cord or a country-specific power cord with earthing
wire and plug. Before making electrical connections carefully check that the voltage supplied is compatible
with the voltage marked on the
device’s
data plate. Any electrical installation work must be carried out by
qualified personnel.
•
The power socket must be easily accessible.
•
Risk of injuries when using not authorized accessories!
•
Therefore, do only use original accessories of Sanosil Ltd.
•
Place device on a stable, flat, dust-free, not slippery, horizontal surface which can appropriately support its weight.
•
Before removing the rear panel, always disconnect the device from the power supply.
•
When there is liquid inside the tank, do not tilt the device; it could leak from the hydraulic circuit.
•
Read carefully all indications stated on the label of the Sanosil disinfectant.
2.4
Authorized Persons
The device shall only be used by adults who have been carefully instructed on how to operate it and are well
informed on possible dangers and risks incurred when using the device.
The users must always have a copy of this Operation Manual at their disposal when operating the device and
have read and understood all specific indications stated on the label of the Sanosil disinfectant used.