Headlight Bulb 

(Standard on some models)

NOTE:  Turn off the switch and unplug the electrical cord before replacing
               headlight bulb.

Headlight style varies by model. Locate the notches that release the tabs at either (1)
top, (2) side, or (3) bottom of the lens, as illustrated. Place a screwdriver into one
notch; twist or pry the screwdriver to release the lens. Repeat for the second notch on
the opposite side.

Rotate the bulb socket forward. Push bulb in and turn to remove. Secure new bulb into
socket and rotate bulb socket backward.

Replace the lens tabs into the top of the bottom of the hood opening. Rotate lens to
position and press down at each notch until the lens locks into position.

NOTE: Use 15 watt replacement bulb, only.

Ask for GENUINE EUREKA replacement bulb, 48815.

1

2

3

14

Summary of Contents for 680 Series

Page 1: ...ion or service information call 1 800 282 2886 En Mexico llame al 5670 6169 www eureka com MODEL TYPE SERIAL NO VOLTS AMPS HERTZ SERVICE INFORMATION 1 800 282 2886 THE EUREKA COMPANY BLOOMINGTON ILLINOIS 61701 Rating Plate The model type and serial numbers are indicated on the rating plate located on the bottom of the cleaner Write these numbers below and refer to them when inquiring about service...

Page 2: ...o a properly grounded outlet only refer to Grounding Instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or vacuum cleaner with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust l...

Page 3: ...outlet installed by a qualified technician This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Figure A A temporary adapter which looks like the adapter illustrated in Figure B may be used to connect this plug to a two pole receptacle as shown if a properly grounded outlet is not available The temporary adapter should be used onl...

Page 4: ... trois mise à la terre Ne pas utiliser des rallonges ou des prises qui n ont pas de capacité suffisante pour transporter le courant Fermer tous les contrôles avant débrancher Ne pas débrancher en tirant sur le cordon Pour débrancher tenez la fiche et non le cordon Ne pas manipuler la fiche ou l aspirateur avec les mains mouillées Ne pas rien insérer dans les ouvertures Ne pas utiliser si des ouver...

Page 5: ...ulter un électricien ou un technicien d entretien qualifié si vous n êtes pas certain que la prise est correctement mise à la terre Ne pas modifier la fiche fournie avec l appareil si elle ne peut être insérée dans la prise faire installer une prise adéquate par un électricien qualifié NOTE Au Canada l utilisation d un adaptateur temporaire n est pas autorisée par le Code canadien de l électricité...

Page 6: ...e Eureka Company Service Division 807 North Main Street Bloomington Illinois 61701 USA In Canada write to The Eureka Company 866 Langs Drive Cambridge Ontario N3H 2N7 DO NOT OIL the motor or the brush roll at any time The bearings are permanently lubricated and sealed HOW TO ASSEMBLE CAUTION Fully assemble the cleaner before using Assembly Packet The assembly packet contains two 2 part handle bolt...

Page 7: ...t at the back of the cleaner Make sure the notches on the lower handle face the rear of the cleaner Fig 1 Align the holes insert a 2 part bolt A and tighten A A Dust Cup Support Tube Lower Handle Handle Socket Upper Handle Lower Handle Handle Socket A A Secure Cord Clamp Secure the electrical cord to the dust cup support with the cord clamp and screw D Place the cord clamp over the electrical cord...

Page 8: ...nd the two cord hooks Fasten the plug to the cord to prevent unwinding 8 Hook Bag Top Slip the ring at the top of the cloth bag over the bag support hook on the back of the cord hook 1 Place inner tab into slot 2 Press hook around handle 3 SNAP opposite inner tab into place Attach Lower Cord Hook Insert the power cord into the lower cord hook A as shown Snap the hook into the lower handle Pull up ...

Page 9: ...elease the handle lock located at the left rear side of the cleaner Move the handle and adjust it to the desired position for 1 storing upright 2 operating the cleaner at a comfortable height for the user and 3 cleaning under neath low furniture Power Switch The power switch is mounted on the motor hood near the handle Switch style varies by model and may differ from the illustration A push with t...

Page 10: ...ifficult to push follow the procedure and test the cleaner at the next higher setting Continue testing the setting until the cleaner is comfortable to move Moving the knob or slide to the next higher setting raises the brush roll slightly making the cleaner easier to push However the brush roll must make contact with the carpet for effective cleaning Recommended Setting Example of Carpet Position ...

Page 11: ...al cord before emptying the dust cup Never operate the vacuum cleaner without the dust cup latched in place 1 Unhook the clip from the top of the cloth bag 2 Shake the cloth bag to release dust clinging inside 3 Release each latch one on either side of the handle push down on the lock lift up on the bottom and pull the top forward NOTE Keep the latch free of dust or obstructions that would prevent...

Page 12: ...en the two end caps Check the condition of the belt change if necessary Replace the brush roll belt and bottom plate see How To Replace A Worn Belt Ask for GENUINE EUREKA replacement brush strip 12 inch No 52282 16 inch No 52246 1 Brush Roll As the brush roll rotates it sweeps and combs the carpet nap Remove hair and threads from the brush roll so it continues brushing the carpet nap When the bris...

Page 13: ...t to rotate unevenly How To Replace A Worn Belt NOTE Turn off the switch and unplug the electrical cord before replacing belt Belt pulleys can become hot during normal use To prevent burns avoid touching the belt pulley when servicing the drive belt IMPORTANT Improper installation of the brush roll or brush roll belt could cause carpet or cleaner damage 2 Pull up on belt to rotate it off the motor...

Page 14: ...nto one notch twist or pry the screwdriver to release the lens Repeat for the second notch on the opposite side Rotate the bulb socket forward Push bulb in and turn to remove Secure new bulb into socket and rotate bulb socket backward Replace the lens tabs into the top of the bottom of the hood opening Rotate lens to position and press down at each notch until the lens locks into position NOTE Use...

Page 15: ...ers drive belts light bulbs brush roll bristles impellers outer bags and cleaning Damages or malfunctions caused by negligence abuse or use not in accordance with the Owner s Guide Defects or damages caused by unauthorized service or the use of other than Genuine Eureka parts WHAT THE EUREKA COMPANY WILL DO The Eureka Company will at its option repair or replace a defective cleaner or cleaner part...

Page 16: ...id by the Warranty Station When returning parts for repair please include the model type and serial numbers from the data plate on the cleaner FURTHER LIMITATIONS AND EXCLUSIONS Any warranty that may be implied in connection with your purchase or use of the cleaner including any warranty of MERCHANTABILITY or any warranty for FITNESS FOR A PARTICULAR PURPOSE is limited to the duration of this warr...

Reviews: