30
Version: 20221219
C.
Re-assembly of the Vibro-I cartridge
For this instruction for re-assembly of the cartridge, please refer to the overview of
components in the previous section.
1.
Make sure that all parts are intact and clean
2.
Place the bottom Vibro-I cushion assembly (2) in the desired orientation by sliding it
over the 4 rods (5).
3.
Place the inner gaskets (3) carefully in the gasket grove of the bottom Vibro-I cushion
assembly. Make sure that the
“
lip
”
of the inner gasket is facing up:
4.
Place the first HP1 module (1) in the desired orientation by sliding it over the rods (5)
and ensure it is perfectly aligned with the Vibro-I cushion assembly.
5.
Place the inner gasket (3) carefully in the gasket grove of the HP1 module
–
again with
the lip facing up
6.
Repeat for the remaining HP1 modules. Make sure they are perfectly aligned with the
previous HP1 modules and that the inner gasket lip is facing up on each module.
Check the alignment by looking into the cavities of the assembly:
A cross-section of the inner gasket placed
correctly with the ‘lip’ on the top right