13
Version: 20221219
4.
Safety
Please be sure to read this entire user manual prior to use of the equipment.
Please read all safety instructions carefully.
This user manual is part of the product. Keep it in a safe place for future reference.
A.
Intended use
The Vibro-I is a filtration system for microfiltration and ultrafiltration that can be operated in
numerous ways both 100% manual, 100% automated and every option in-between. The user
should read and understand this manual before use. The Vibro-I is intended for use in an
industrial or research facility.
The Vibro-I is intended to filter media and can only be used with HP1 membrane modules
from SANI Membranes.
The Vibro-I can only be used together with a feed system with a built-in safety to protect the
Vibro-I against over-pressure. If the feed system is able to deliver over-pressure, a CE
approved safety valve set to the applicable maximum operating pressure of the Vibro-I
system must be included before the Vibro-I inlet.
The applicable operating pressure range of the system is 0-4 bar(g) at 5-35 °C, 0-3 bar(g) at 5-
55 °C and 0-1 bar(g) at up to 80°C.
The Vibro-I is a vibrating machine product that must be placed on a foundation that can
absorb the reactions from the vibrations. Preferable vibration absorption is through suitable
heavy flooring or foundations. Be aware that eigenfrequency or natural frequency response in
buildings can lead to structural damage.
WARNING
The Vibro-I is NOT suited for use in explosive environments.