10
Version: 20221219
The Vibro-I cushion assembly (11) consists of
15.
Vibro-I cushion
16.
Media inlet/outlet part
17.
Top/bottom part
18.
Media inlet/outlet ports
The Vibro-I cushion (15) is secured between a media inlet/outlet part (16) and a top/bottom
part (17). Each media inlet/outlet part (16) is configured with up to two media inlet/outlet
ports (18). The ports are for the feed and retentate connections, and for possible vent and/or
connection to instruments such as pressure transducer or temperature sensor.
The Vibro-I cartridge consists of a number of stacked HP1 2.5 m²
membrane modules (9) assembled with a cushion assembly (11) at
the top and at the bottom of the HP1 stack. An internal square o-
ring (10) seals between the assembly parts.
The Vibro-I cartridge is assembled on a bottom plate with four rods
(12) and the complete cartridge is tightened by four nuts (13). For
the 20 m² the rods are extended using threaded bushing with o-
rings and extension rods (14).
The Vibro-I cartridge can be directly lifted onto the Vibro-I drive frame by placing lifting eyes
on top of two of the rods. When positioned on the motor assembly, the cartridge is mounted
on the base plate (7) using four bolts.
HP1 module with
permeate ports
Vibro-I Cushion Assembly
Bottom inlet assembly shown