Thank you for  placing your confidence in S&P by buying this product. It has been manufactured following current 
technical safety regulations and in compliance with EC standard. 
 
Please  read  this  instructions  booklet  carefully  before  installing  or  starting  up  the  product.  It  contains  important 
information  on  personal  and  user  safety  measures  to  be  followed  while  installing,  using  and  carrying  out 
maintenance work on the equipment. Once the product has been  installed, please hand in this booklet to the end 
user. 
 
Check that the apparatus is in perfect condition while unpacking. Any fault or damage caused in origin is covered 
by the S&P guarantee. Please make sure that the apparatus coincides with the product you have ordered and that 
the details on the instructions plate fulfil your necessities. 
 
Transport and manipulation. 

-

 

The  packaging  used  for  this  apparatus  has  been  designed  to  support  normal  transporting  conditions.  The 
apparatus must  always  be transported  in  its original packaging  as not  doing  so could deform  or  damage  the 
product. 

-

 

The product  should be  stored  in  a  dry  place  in  its  original  packaging,  protected  from  dust  and  dirt until  it  is 
installed  in  its  final  location.  Do  not  accept  delivery  if  the  apparatus  is not in  its  original packaging or shows 
clear signs of having been manipulated in any way. 

-

 

Do not place heavy weights on the packed product and avoid knocking or dropping it. 

-

 

When manipulating heavy products, adequate elevating machinery should be used to avoid harming people or 
damaging the product itself. 

-

 

Never lift a product by pulling it by the wires or terminal casing. Likewise, no pressure should be applied on the 
propeller, turbine or safety grid while manipulating the product. 

 
Important information for the safety of installers and users. 

-

 

Installation must only be carried out by qualified persons. 

-

 

Make sure that the installation complies with each country’s current mechanical and electrical norms. 

-

 

Once ready to use, the apparatus must fulfil the following standards: 

·

 

Standard for Low Pressure Instalments 2006/95/CE 

·

 

Machinery Standard 2006/42/CE 

·

 

Standard for Electromagnetic Compatibility 2004/108/CE. 

-

 

Ventilators installed in high risk areas (1) that are accessible to users must be adequately protected in order to 
comply with  the Standards. The necessary protective devices can be found  in the accessories  section of  the 
general S&P catalogue. 

-

 

Any area in or around a machine, where the presence of people can cause situations of danger for their safety 
or health, can be considered a high risk area. 

-

 

Ventilators, or apparatus that include them , have been designed to move the air in the area stipulated on their 
characteristics plate. 

-

 

This apparatus must not be used in explosive or corrosive atmospheres (2). 

-

 

If a machine is needed for working in the previously stated conditions, consult the S&P Technical Service. 

-

 

If the apparatus is going to be used in atmospheres with over 95% relative humidity, consult the S&P Technical 
Service first. 

-

 

If a ventilator is going to be installed to extract air from premises where a boiler or other combustion apparatus 
are installed, make sure that the building has sufficient air intakes to assure adequate combustion. 

 
Safety during installation. 

-

 

Make sure there are no loose elements near the ventilator, as they could run the risk of being sucked up by it. If 
it  is  going  to  be  installed  in  a  duct,  check  that  it  is  clean  of  any  element  that  could  be  sucked  up  by  the 
ventilator. 

-

 

When installing an apparatus, make sure that all the fittings are in place and that the structure which supports it 
is resistant enough to bear its weight at full functioning power. 

-

 

Before  manipulating  the  apparatus,  make  sure  the  mains  supply  is  disconnected,  even  if  the  machine  is 
switched off. 

-

 

Check that the mains supply voltage and frequency values coincide with the stipulations on the characteristics 
plate. 

-

 

Please follow the connections diagram for the electrical connections. 

-

 

If  an  earth  connection  is  necessary,  check  that  it  correctly  connected  and  that  adequate  thermal  and 
overloading protection has been connected and adjusted to the corresponding limits. 

-

 

If a ventilator is installed in a duct, the duct must be exclusively for the ventilation system. 

Summary of Contents for CAB-PLUS Series

Page 1: ...CAB PLUS...

Page 2: ...aune VR Velocidad r pida High speed Grande vitesse VL Velocidad lenta Low speed petite vitesse 1 2 3 L N 230V 50Hz VL C D A B VR M CAB PLUS 125 CAB PLUS 160 CAB PLUS 250 A Azul Blue Bleu B Blanco Whit...

Page 3: ...entilador en una zona peligrosa 1 accesible para los usuarios para cumplir las Directivas es necesario montar las protecciones adecuadas que se pueden localizar en el apartado de Accesorios del Cat lo...

Page 4: ...desconectado de la red aunque ya est parado y de que nadie pueda ponerlo en marcha durante la intervenci n Es necesaria una inspecci n regular del aparato La frecuencia de la misma debe ser en funci...

Page 5: ...wing standards Standard for Low Pressure Instalments 2006 95 CE Machinery Standard 2006 42 CE Standard for Electromagnetic Compatibility 2004 108 CE Ventilators installed in high risk areas 1 that are...

Page 6: ...ins supply even if it has previously been switched off Prevent the possibility of anyone else connecting it while it is being manipulated The apparatus must be regularly inspected These inspections sh...

Page 7: ...s une zone dangereuse 1 accessible pour les utilisateurs il faudra pour r pondre aux Directrives monter les protections appropri es d crites dans le chapitre Accessoires du Catalogue G n ral de S P No...

Page 8: ...uisse le mettre en marche pendant l op ration Une inspection r guli re de l appareil est n cessaire Sa fr quence doit tre fix e en fonction des conditions de travail afin d viter l accumulation de sal...

Page 9: ...iebnahme muss das Ger t folgende Richtlinien erf llen Niederspannungsrichtlinie 2006 95 CE Maschinenrichtlinie 2006 42 CE Richtlinie zur elektromagnetischen Vertr glichkeit 2004 108 CE Soll der Ventil...

Page 10: ...dem Wiedereinschalten Wartung Wartungsarbeiten d rfen ausschlie lich durch ausgebildetes Fachpersonal und nach den jeweils geltenden nationalen Vorschriften durchgef hrt werden Vor allen Arbeiten am...

Page 11: ...De machinerichtlijn 2006 42 EG EMC richtlijn Elektromagnetische Compatibiliteit 2004 108 EG Indien een ventilator wordt ge nstalleerd in een gevaarlijke zone 1 die toegankelijk is voor de gebruikers m...

Page 12: ...el het apparaat dat van het elektrisch net en controleer de installatie alvorens deze opnieuw in bedrijf te stellen Onderhoud Controleer altijd eerst of dit apparaat is losgekoppeld van het elektricit...

Page 13: ...dade Electromagn tica 2004 108 CE Se instalar um ventilador numa zona perigosa 1 qual podem ter acesso os utilizadores para cumprir as Directivas ser necess rio instalar as protec es adequadas que se...

Page 14: ...mbora esteja parado e que ningu m pode p lo em funcionamento durante a interven o necess ria uma inspec o regular do aparelho A frequ ncia da mesma dever ser em fun o das condi es de trabalho para evi...

Page 15: ...Se si installa un ventilatore in una zona pericolosa 1 accessibile agli utenti per rispettare le Direttrici necessario montare le protezioni adeguate che si possono localizzare nel paragrafo Accessor...

Page 16: ...re che disinserito anche se fermo e che nessuno possa metterlo in funzione durante l intervento necessaria un ispezione regolare dell apparecchio La sua frequenza deve essere in funzione delle condizi...

Page 17: ...netick kompatibility 2004 108 EWG Je li ventil tor nainstalov n v nebezpe n m p smu 1 do n ho m u ivatel umo n n p stup je z d vodu dodr en sm rnic nutn um stit ochrany uveden v odstavci P slu enstv v...

Page 18: ...vypnut aby ho dn ze zam stnanc nemohl p i dr b uv st do chodu Prov d jte pravideln revize spot ebi e asov interval mezi jednotliv mi revizemi z vis na provozn ch podm nk ch Snahou pravideln ch kontrol...

Page 19: ...Direktiv f r maskiner 2006 42 CE Direktiv f r elektromagnetisk kompatibilitet 2004 108 CE Om en fl kt installeras i en riskzon 1 men tillg nglig f r anv ndarna r det n dv ndigt att montera de skydd so...

Page 20: ...ven om den r avst ngd och att ingen kan s tta ig ng den under tiden Det r n dv ndigt med en regelbunden inspektion Frekvensen f r denna inspektion b r best mmas beroende p anv ndande och milj f r att...

Page 21: ...tilator i en farezone 1 der er tilg ngelig for brugere skal der for opfyldelse af de g ldende direktiver installeres passende beskyttelse som vist i S P s generelle reservedels katalog Som farligt bet...

Page 22: ...ldelse F r enhver manipulation af ventilatoren skal denne v re afbrudt fra el forsyningen selv n r denne er stoppet og ingen b r kunne starte den s l nge den unders ges Apparatet skal inspiceres regel...

Page 23: ...w strefach wysokiego ryzyka Strefa 1 np azienka b d ce dost pne dla u ytkownik w musz by odpowiednio zabezpieczone aby by w zgodzie z Dyrektywami Strefa uznana za niebezpieczn to dowolna strefa wewn...

Page 24: ...czy nikt nie mo e go uruchomi podczas prac konserwacyjnych Konieczna jest regularna kontrola urz dzenia Jej systematyczno powinna odpowiada warunkom pracy aby unikn gromadzenia si brudu na wirniku tu...

Page 25: ...Pavojinga zona laikoma bet kuri zona ma inos viduje ir ar i or je asmens buvimas kurioje reik t rizik jo paties saugumui ar sveikatai Ventiliatoriai ar aparatai kurie juos turi yra sukurti judinti or...

Page 26: ...mpint pastebimai aparato veikimo laikotarp Valymo veiksmai turi b ti labai atsarg s kad nei derinti propelerio ar turbinos Visuose prie i ros ir taisymo darbuose turi b ti atsi velgta saugos normas ve...

Page 27: ...S P CE S P 2006 95 2006 42 2004 108 EOK S P 2 S P 95 S P...

Page 28: ...10 CEE S P After Sales www solerpalau com...

Page 29: ...S P S P 2006 95 CE 2006 42 CE 2004 108 CE 1 S P...

Page 30: ...S P www solerpalau com...

Page 31: ...S P S P 2006 95 CE 2006 42 CE 2004 108 CE 1 S P 2 S P 95 S P 10...

Page 32: ...S P www solerpalau com...

Page 33: ...S P S P o 2006 95 2006 42 2004 108 1 S P 95 3...

Page 34: ...S P...

Page 35: ...akine standard Elektromanyetik uyumluluk i in 2004 108 CE standard Y ksek risk ta yan alanlara yerle tirilmi olan vantilat rlerin standartlara uygun olmas i in kullan c yeterli korumay sa lam olmal d...

Page 36: ...ce kontrol edilmelidir BAKIM Bak m ndan nce cihaz kapat lm olsa bile elektrik ba lant s n n ana kaynaktan kesilmi oldu undan emin olunuz Cihaz al rken ba ka ah slar taraf ndan m dahale edilme olas l n...

Page 37: ...S P S P 2006 95 CE 2006 42 2004 108 1 S P 2 S P 95 S P 10...

Page 38: ...S P S P www solerpalau com...

Page 39: ...bilitatea Electromagnetica 2004 108 CE Ventilatoarele instalate in zone de risc ridicat 1 ce sunt accesibile utilizatorilor trebuie protejate in mod corespunzator pentru a respecta standardele Dispozi...

Page 40: ...tat de la sursa de alimentare chiar daca este oprit Preveniti posibilitatea de a fi reconectat in timpul manipularii Echipamentul trebuie intretinut periodic Aceste inspectii trebuie facute avand in v...

Page 41: ......

Page 42: ......

Page 43: ......

Page 44: ......

Page 45: ......

Page 46: ......

Page 47: ......

Page 48: ...0 Soler Palau Sistemas de Ventilaci n S L U C Llevant 4 08150 Parets del Vall s BCN ESPA A TEL 34935719300 FAX 34935719301 FAX INTERNACIONAL 34935719311 e mail consultas solerpalau com WEB www solerpa...

Reviews: