 S&C Instruction Sheet 665-506   

3

Introduction

Warranty

The warranty and/or obligations described in S&C’s standard conditions of sale, as set 
forth in Price Sheet 150, plus any special warranty provisions, as set forth in the applicable 
product-line specification bulletin, are exclusive .  The remedies provided in the former 
for  breach  of  these  warranties  shall  constitute  immediate  purchaser’s  or  end  user’s 
exclusive remedy and a fulfillment of all seller’s liability .  In no event shall seller’s liability 
to immediate purchaser or end user exceed the price of the specific product which gives 
rise to immediate purchaser’s or end user’s claim .  All other warranties whether express 
or implied or arising by operation of law, course of dealing, usage of trade or otherwise, 
are excluded .  The only warranties are those stated in Price Sheet 150, and THERE ARE 
NO EXPRESS OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 
A  PARTICULAR  PURPOSE .   ANY  EXPRESS  WARRANTY  OR  OTHER  OBLIGATION 
PROVIDED IN PRICE SHEET 150 IS GRANTED ONLY TO THE IMMEDIATE PURCHASER 
AND END USER, AS DEFINED THEREIN .  OTHER THAN AN END USER, NO REMOTE 
PURCHASER MAY RELY ON ANY AFFIRMATION OF FACT OR PROMISE THAT RELATES 
TO THE GOODS DESCRIBED HEREIN, ANY DESCRIPTION THAT RELATES TO THE 
GOODS, OR ANY REMEDIAL PROMISE INCLUDED IN PRICE SHEET 150 .

The seller’s warranties are contingent upon the installation and adjustment of PME 

pad-mounted gear in accordance with S&C’s applicable instruction sheets, data sheets, 
and/or data bulletins .

The standard warranty contained in seller’s standard con ditions of sale (as set forth 

in Price Sheet 150) does not apply to S&C Manual PME Pad-Mounted Gear where fuse 
units,  fuse-unit  end  fittings,  holders,  refill  units,  or  switch  blades  of  other  than  S&C 
manufacture are used in con junction with S&C SME Mountings . Nor does it apply to S&C 
Manual PME Pad-Mounted Gear where other than Fault Fiter Electronic Power Fuses, 
S&C Switch Blades, or selected current-limiting fuses are used in conjunction with Fault 
Fiter Electronic Power Fuse Mountings and S&C Holders designed therefor, or when 
current-limiting fuses are applied other than as set forth under “Current-Limiting Fuses 
for Use in S&C PME Pad-Mounted Gear,” in S&C Instruction Sheet 665-510 .

Summary of Contents for PME Pad-Mounted Gear

Page 1: ...Instruction Sheet 2 Retain this Instruction Sheet 2 Proper Application 2 General 2 Warranty 3 Safety Information Understanding Safety Alert Messages 4 Following Safety Instructions 4 Replacement Instr...

Page 2: ...nt in this publication is only intended for a specific application The application must be within the ratings furnished for the equipment Ratings for this gear are listed on the ratings label on the i...

Page 3: ...ED ONLY TO THE IMMEDIATE PURCHASER AND END USER AS DEFINED THEREIN OTHER THAN AN END USER NO REMOTE PURCHASERMAYRELYONANYAFFIRMATIONOFFACTORPROMISETHATRELATES TO THE GOODS DESCRIBED HEREIN ANY DESCRIP...

Page 4: ...TICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do not understand any po...

Page 5: ...ng carrier immediately 1 Ask for a carrier inspection 2 Note condition of shipment on all copies of the delivery receipt 3 File a claim with the carrier 4 If concealed damage is discovered Notify the...

Page 6: ...d the actuator reaches its stop Refer to Figure 2 This single motion unlatches the mechanism and recharges the latching spring for the subsequent closing operation Pull the door open and secure it wit...

Page 7: ...h the door Pull outward on the cover of the Penta Latch Mechanism to verify that the door has latched securely If it has not use a pentahead or hexhead when applicable socket wrench or tool to rotate...

Page 8: ...enclosure will be bolted directly to the mounting pad using user furnished B inch diameter anchor bolts and supplied hardware Refer to the anchor bolt detail in Figure 4 Anchor brackets and hold down...

Page 9: ...enclosure NOTICE To avoid interference with the TransFuser Mountings the cables to be connected to the fuse terminals must be fed between the horizontal cable guides Special cable training is not requ...

Page 10: ...be assembled to the unit First bolt one of the large deflectors to the bottom of a switch or fuse compart ment frame using the supplied B zn inch serrated nuts Refer to Figures 6 7 and 8 Repeat for t...

Page 11: ...led behind the two large deflectors Then bolt the small deflector into place using the supplied B zn inch serrated nuts Confirm that the complete deflector assembly installation matches Figure 7 on pa...

Page 12: ...elbows and inserts Appropriate elbowsm and inserts must be supplied and installed by the user Before installing elbows and inserts remove the shipping covers from bushings and bushing wells Ground eac...

Page 13: ...tral ground wires to the ground bails and rods provided making sure that cables have sufficient mobility to allow the elbows to be moved from bushings to parking stands Connect the ground pads inside...

Page 14: ...nd replace the bolts to plug the blind tapped holes 1 Check the interior of the pad mounted gear Remove all foreign materials and tools 2 that may have been mislaid and sweep the interior clear of deb...

Page 15: ...onducted at no more than 0 75 times the values shown When making ac tests the time duration for application of the test voltage should be limited to less than 10 seconds 3 The column headed Dc is give...

Page 16: ...Stainless Steel Enclosure1 With Olive Green Outdoor Ultradur Finish A10 With Light Gray Outdoor Ultradur Finish A12 Hexhead Actuator for use in lieu of pentahead actuator on all Penta Latch Mechanism...