background image

4

   

S&C Instruction Sheet 665-506

Safety Information

Understanding 
Safety-Alert Messages

There  are  several  types  of  safety-alert  messages  which  may  appear  throughout  this 
instruction sheet as well as on labels attached to the S&C Manual PME Pad-Mounted 
Gear . Familiarize yourself with these types of messages and the importance of the various 
signal words, as explained below .

Ç

 DANGER

“DANGER”  identifies  the  most  serious  and  immediate  hazards  which 

will  likely

 

result in serious personal injury or death if instructions, including recommended 
precautions, are not followed .

Ç

 WARNING

“WARNING”  identifies  hazards  or  unsafe  practices  which 

can

  result  in  serious 

personal injury or death if instructions, including recommended precautions, are 
not followed .

Ç

 CAUTION

“CAUTION” identifies hazards or unsafe practices which 

can

 result in minor personal 

injury  or  product  or  property  damage  if  instructions,  including  recommended 
precautions, are not followed .

NOTICE

“NOTICE” identifies important procedures or requirements that 

can

 result in product 

or property damage if instructions are not followed .

Following 
Safety Instructions

If you do not understand any portion of this instruction sheet and need assistance, contact 
your nearest S&C Sales Office or S&C Autho rized Distributor, or call S&C Headquarters 
at (773) 338-1000, Monday through Friday between 8:30 AM and 5:00 PM Central Standard 
Time . (In Canada, call S&C Electric Canada Ltd . at (416) 249-9171, Monday through Friday 
between 8:00 AM and 5:00 PM Eastern Standard Time .)

Ç

 DANGER

Read this instruction sheet thoroughly and carefully 
before installing or operating your S&C Manual PME 
Pad-Mounted Gear .

Replacement  
Instructions  
and Labels

If you need additional copies of this instruction sheet, contact your nearest S&C Sales 
Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric Canada Ltd .

It is important that any missing, damaged, or faded labels on the equipment be 

replaced immediately . Replacement labels are available by contacting your nearest 
S&C Sales Office, S&C Authorized Distributor, S&C Headquarters, or S&C Electric 
Canada Ltd .

Summary of Contents for PME Pad-Mounted Gear

Page 1: ...Instruction Sheet 2 Retain this Instruction Sheet 2 Proper Application 2 General 2 Warranty 3 Safety Information Understanding Safety Alert Messages 4 Following Safety Instructions 4 Replacement Instr...

Page 2: ...nt in this publication is only intended for a specific application The application must be within the ratings furnished for the equipment Ratings for this gear are listed on the ratings label on the i...

Page 3: ...ED ONLY TO THE IMMEDIATE PURCHASER AND END USER AS DEFINED THEREIN OTHER THAN AN END USER NO REMOTE PURCHASERMAYRELYONANYAFFIRMATIONOFFACTORPROMISETHATRELATES TO THE GOODS DESCRIBED HEREIN ANY DESCRIP...

Page 4: ...TICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If you do not understand any po...

Page 5: ...ng carrier immediately 1 Ask for a carrier inspection 2 Note condition of shipment on all copies of the delivery receipt 3 File a claim with the carrier 4 If concealed damage is discovered Notify the...

Page 6: ...d the actuator reaches its stop Refer to Figure 2 This single motion unlatches the mechanism and recharges the latching spring for the subsequent closing operation Pull the door open and secure it wit...

Page 7: ...h the door Pull outward on the cover of the Penta Latch Mechanism to verify that the door has latched securely If it has not use a pentahead or hexhead when applicable socket wrench or tool to rotate...

Page 8: ...enclosure will be bolted directly to the mounting pad using user furnished B inch diameter anchor bolts and supplied hardware Refer to the anchor bolt detail in Figure 4 Anchor brackets and hold down...

Page 9: ...enclosure NOTICE To avoid interference with the TransFuser Mountings the cables to be connected to the fuse terminals must be fed between the horizontal cable guides Special cable training is not requ...

Page 10: ...be assembled to the unit First bolt one of the large deflectors to the bottom of a switch or fuse compart ment frame using the supplied B zn inch serrated nuts Refer to Figures 6 7 and 8 Repeat for t...

Page 11: ...led behind the two large deflectors Then bolt the small deflector into place using the supplied B zn inch serrated nuts Confirm that the complete deflector assembly installation matches Figure 7 on pa...

Page 12: ...elbows and inserts Appropriate elbowsm and inserts must be supplied and installed by the user Before installing elbows and inserts remove the shipping covers from bushings and bushing wells Ground eac...

Page 13: ...tral ground wires to the ground bails and rods provided making sure that cables have sufficient mobility to allow the elbows to be moved from bushings to parking stands Connect the ground pads inside...

Page 14: ...nd replace the bolts to plug the blind tapped holes 1 Check the interior of the pad mounted gear Remove all foreign materials and tools 2 that may have been mislaid and sweep the interior clear of deb...

Page 15: ...onducted at no more than 0 75 times the values shown When making ac tests the time duration for application of the test voltage should be limited to less than 10 seconds 3 The column headed Dc is give...

Page 16: ...Stainless Steel Enclosure1 With Olive Green Outdoor Ultradur Finish A10 With Light Gray Outdoor Ultradur Finish A12 Hexhead Actuator for use in lieu of pentahead actuator on all Penta Latch Mechanism...