SRG-1150DN / SRG-1250DN / SN-100
(1) SCAN TYPE SET
a) Decide Scanning Channel or Frequency
b) After〔1.Scan Type Set〕 is inverted using [ ▲ ] [ ▼ ] KEY,
press [ ENTER] KEY and then display is indicated
c) In this mode, selected Scan Type is fixed.
ex) In case of Scan Type is ch. - Scan channel
In case of Freq. - Scan Freq.
d) Press [ CLR] key, changed to main display.
(2) SCAN CHANNEL SET
a) Fix setting value in case of scanning Channel.
b) After [ 2.Scan Channel Set] is inverted using [ ▲ ] [ ▼ ] KEY,
press [ ENTER] KEY and then display is indic ated.
Start
Last
Speed
:
:
:
001 - -
299
0
c) After moving cursor using [ ▲ ] [ ▼ ] [ ◀ ] [ ▶ ] KEY, set value using
figure key and then press [ ENTER] KEY
d) [ Start] : Set starting channel of Scan Channel.
[ Last] : Set last Scan Channel.
[ Speed] :Set Scan Channel Speed
(3) SCAN FREQUENCY SET
a) Set setting value in case of scanning FREQUENCY
b) After [ 3.Scan Frequency Set] is converted using [ ▲ ] [ ▼ ] KEY,
press [ ENTER] KEY and then following display is indicated.
Start
Last
Speed
Step
:
:
:
:
00.500.0 - -
29,999,9 KHz
0
001(100Hz)
c) After moving cursor using [ ▲ ] [ ▼ ] [ ◀ ] [ ▶ ] KEY, set value using
figure key and press [ ENTER] KEY
d) [ Start] : Set starting frequency of Scan Frequency.
[ Last] : Set last frequency of Scan Frequency.
[ Speed] : Set Scan Frequency Speed.
[ S tep] : Set Scanning frequency STEP(100HZ per 1Step)
ex ) When‘ 100’ - 10KHz STEP