SRG-1150DN / SRG-1250DN / SN-100
3. POWER SUPPLY
3.1 POWER ON
a) AC power plug put in plug receptacle, connect the battery with rear socket.
b) AC and DC switch on.
c) Check the indication of light on : AC IN, DC IN, DC OUT of Front panel.
d) Connect cables between SRG- 1150DN/SRG- 1250DN and SN- 100.
(Only when NBDP terminal is being used.)
e) Press SRG- 1150DN/SRG- 1250DN [ PWR] key.
f) Press power switch of SN- 100.(Only when NBDP terminal is being used.)
3.2 OPERATION BY AC POWER
When AC power is supplied to the main unit, it works with on AC power
automatically. W/K LED displays the condition that 6 scanning frequency is working
on DSC WKR of transceiver.
In this mode, if a DSC distress or DSC alarm call is received, the [ DISTRESS] of
[ OTHERS] LEDs on MF/HF control panel will light up and the alarm tone is sounded.
(Refer to 'Operation of Distress Acknowledge Signal' on 1p for operation
instructions if a DSC distress or DSC alarm call is received.)
3.3 OPERATION BY DC POWER
When AC power is disconnected, the SRG- 1250DN switches to the DC operation
and the [ DC] LED on MF/HF control panel will light up automatically.
When it is transmitted to DSC, AC signal will be changed to DC on upside of
transceiver LCD display. Moreover, changing to DC mode will be displayed on
downside of that.
And receiving output is converted to LOW.
3.4 BATTERY CHARGING
When connected to AC power, except of switch on of transmitter power supply
AMP power, the battery is automatically charged. While charging, a 20A static current
is supplied to the battery, when fully charged, a low current is supplied to maintain
the rated battery voltage. The charge mode indicator between automatic and normal
is by the charge switch on the system cabinet.
AUTO MODE - When the battery is low, automatically charge. The default is auto
mode.
NORMALㅤMODE - Regardless of battery status, charge the battery.
To make battery life long, it needs repair properly. Refer to the manual.