Samsung Electronics
2. Check Point about the Radiant Heat
14
Standard and condition for indoor installation
-
Standard for using ‘SAMSUNG WALL MOUNT’ (Fulfill ADA)
-
Ceiling installation, outdoor installation, cannot be installed where there is
vibration
It is not possible to install it in a special case, and it is necessary to consult technical sales
separately.
-
In principle, solar window direct radiation condition installation is avoided.
-
Window side, adjacent installation
. A weak solar scan of the time zone except for the noon time zone during work is allowed
. If surface temperature rise is minor (1 ~ 2 degrees) allowed
. Use UV blocking / light blocking film when installation of window adjacent is inevitable.
- Room temperature is recommended to be 0 ~ 25 ℃
- Effect of Cold / Hot Wind on Air Conditioning System
. If the cold or hot air is the same air conditioning system, be careful not to affect the product.
- Air temperature measurement position
. Based on product center or air let part
※ ADA(American’s with Disabilities Act
98.6mm
26.1mm
wall
Measuring
location for
ambient
temperature
Measuring
location for
ambient
temperature
※ Written under ‘Full white, (back light 7)’ standard